The critical heat flux (CHF) in a saturated pool boiling of water was investigated experimentally under the condition in which a honeycomb porous plate is attached to the heated surface. In a previous study, the CHF was shown experimentally to be approximately 2.5 times (approximately 2.51 MW/m2) compared to that of a plain surface for the case of a honeycomb porous plate with a vapor escape channel width of 1.4 mm and a channel height (plate thickness) of 1.0 mm (Mori and Okuyama (2009)). The enhancement is considered to result from the capillary supply of liquid onto the heated surface and the release of generated vapor through the channels. In the present paper, the vapor escape channel width was varied in the range of 1.4 mm to 7.9 mm, which was smaller than the Taylor instability wavelength (approximately 15.6 mm), and the effect of the channel width on the saturated pool boiling CHF of water has been investigated. The CHF values predicted by capillary limit models were compared with measured values. As a result, the main mechanisms for CHF enhancement using a honeycomb porous plate were shown to be due to liquid supply to the heated surface as a result of not only capillary suction but also the inflow of liquid through vapor escape channels from the top surface due to gravity. The ratio of the contribution in the mechanisms of the CHF enhancement was found to depend on the vapor escape channel widths. In particular, in the case of a larger cell width, the CHF was enhanced primarily due to the inflow of liquid through vapor escape channels from the top surface.
Skip Nav Destination
2010 14th International Heat Transfer Conference
August 8–13, 2010
Washington, DC, USA
Conference Sponsors:
- Heat Transfer Division
ISBN:
978-0-7918-4936-1
PROCEEDINGS PAPER
Effect of Cell Size of a Honeycomb Porous Plate Attached to a Heated Surface on CHF in Saturated Pool Boiling
Shoji Mori,
Shoji Mori
Yokohama National University, Yokohama, Kanagawa, Japan
Search for other works by this author on:
Lujie Shen,
Lujie Shen
Yokohama National University, Yokohama, Kanagawa, Japan
Search for other works by this author on:
Kunito Okuyama
Kunito Okuyama
Yokohama National University, Yokohama, Kanagawa, Japan
Search for other works by this author on:
Shoji Mori
Yokohama National University, Yokohama, Kanagawa, Japan
Lujie Shen
Yokohama National University, Yokohama, Kanagawa, Japan
Kunito Okuyama
Yokohama National University, Yokohama, Kanagawa, Japan
Paper No:
IHTC14-22349, pp. 255-265; 11 pages
Published Online:
March 1, 2011
Citation
Mori, S, Shen, L, & Okuyama, K. "Effect of Cell Size of a Honeycomb Porous Plate Attached to a Heated Surface on CHF in Saturated Pool Boiling." Proceedings of the 2010 14th International Heat Transfer Conference. 2010 14th International Heat Transfer Conference, Volume 1. Washington, DC, USA. August 8–13, 2010. pp. 255-265. ASME. https://doi.org/10.1115/IHTC14-22349
Download citation file:
16
Views
Related Proceedings Papers
Related Articles
Investigation of Pool Boiling Critical Heat Flux Enhancement on a Modified Surface Through the Dynamic Wetting of Water Droplets
J. Heat Transfer (July,2012)
Orientation Effects on Critical Heat Flux From Discrete, In-Line Heat Sources in a Flow Channel
J. Heat Transfer (November,1993)
An Experimental Study of Boiling in Reduced and Zero Gravity Fields
J. Heat Transfer (August,1961)
Related Chapters
Pool Boiling
Thermal Management of Microelectronic Equipment, Second Edition
New Calculation Method of Tunnel Water Inflow Quantity and It's Application in Qiyueshan Tunnel
Geological Engineering: Proceedings of the 1 st International Conference (ICGE 2007)
Hydro Power Generation: Global and US Perspective
Energy and Power Generation Handbook: Established and Emerging Technologies