This paper presents an experimental investigation of the forced convective boiling of refrigerant HCFC123 in a mini-tube. The inner diameters of the test tubes, D, were 0.51 mm and 0.30 mm. First, two-phase frictional pressure drops were measured under adiabatic conditions and compared with the correlations for conventional tubes. The frictional pressure drop data were lower than the correlation for conventional tubes. However, the data were qualitatively in accord with those for conventional tubes and were correlated in the form φL2−1/Xtt. Next, heat transfer coefficients were measured under the conditions of constant heat flux and compared with those for conventional tubes and for pool boiling. The heat transfer characteristics for mini-tubes were different from those for conventional tubes and quite complicated. The heat transfer coefficients for D = 0.51 mm increased with heat flux but were almost independent of mass flux. Although the heat transfer coefficients were higher than those for a conventional tube with D = 10.3 mm and for pool boiling in the low quality region, they decreased gradually with increasing quality. The heat transfer coefficients for D = 0.30 mm were higher than those for D = 0.51 mm and were almost independent of both mass flux and heat flux.
Skip Nav Destination
2010 14th International Heat Transfer Conference
August 8–13, 2010
Washington, DC, USA
Conference Sponsors:
- Heat Transfer Division
ISBN:
978-0-7918-4936-1
PROCEEDINGS PAPER
Forced Convective Boiling of Refrigerant HCFC123 in a Mini-Tube
Koichi Araga,
Koichi Araga
Kinki University Technical College, Kumano, Mie, Japan
Search for other works by this author on:
Keisuke Okamoto,
Keisuke Okamoto
Kinki University Technical College, Kumano, Mie, Japan
Search for other works by this author on:
Keiji Murata
Keiji Murata
Kinki University Technical College, Kumano, Mie, Japan
Search for other works by this author on:
Koichi Araga
Kinki University Technical College, Kumano, Mie, Japan
Keisuke Okamoto
Kinki University Technical College, Kumano, Mie, Japan
Keiji Murata
Kinki University Technical College, Kumano, Mie, Japan
Paper No:
IHTC14-22060, pp. 139-146; 8 pages
Published Online:
March 1, 2011
Citation
Araga, K, Okamoto, K, & Murata, K. "Forced Convective Boiling of Refrigerant HCFC123 in a Mini-Tube." Proceedings of the 2010 14th International Heat Transfer Conference. 2010 14th International Heat Transfer Conference, Volume 1. Washington, DC, USA. August 8–13, 2010. pp. 139-146. ASME. https://doi.org/10.1115/IHTC14-22060
Download citation file:
6
Views
Related Proceedings Papers
Related Articles
Water-Heated Pool Boiling of Different Refrigerants on the Outside Surface of a Horizontal Smooth Tube
J. Heat Transfer (February,2012)
Pool Boiling of R514A, R1224 yd(Z), and R1336mzz(E) on a Reentrant Cavity Surface
J. Heat Transfer (May,2021)
Nucleate Pool Boiling Heat Transfer of R134a and R134a-PVE Lubricant Mixtures on Smooth and Five Enhanced Tubes
J. Heat Transfer (November,2010)
Related Chapters
Post-CHF Heat Transfer in Flow Boiling
Two-Phase Heat Transfer
Liquid Cooled Systems
Thermal Management of Telecommunications Equipment
Fundamentals of Convective and Boiling Heat Transfer
Thermal Design of Liquid Cooled Microelectronic Equipment