This paper presents the design, control, and validation of a soft robotic exoskeleton system, the REHAB Glove, for hand rehabilitation. The system is comprised of five hybrid soft-and-rigid robotic digits that apply controlled flexion and extension motion to fingers. The previous actuator design of the soft robotic digit was improved for kinematic compatibility with anatomical motions of the hand in relation to range of motion, center of rotation, and dorsal skin lengthening. The design was validated using motion capture and analysis. A position control algorithm, which controls finger angular trajectories (angular position and velocity), was developed based on motion sensor feedback. The operation of this algorithm was verified using a 90° digit tip trajectory with two angular velocities of 15°/sec and 30°/sec. A pilot study was carried out with five healthy individuals to evaluate the performance of the REHAB Glove in providing therapeutic schemes. The results show that the REHAB Glove is able to provide controlled motion compatible with the kinematics and dynamics of the human.
Skip Nav Destination
ASME 2017 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference
August 6–9, 2017
Cleveland, Ohio, USA
Conference Sponsors:
- Design Engineering Division
- Computers and Information in Engineering Division
ISBN:
978-0-7918-5815-8
PROCEEDINGS PAPER
Soft Robotic Rehabilitation Exoskeleton (REHAB Glove) for Hand Therapy
Mahdi Haghshenas-Jaryani,
Mahdi Haghshenas-Jaryani
University of Texas at Arlington, Fort Worth, TX
Search for other works by this author on:
Caleb Nothnagle,
Caleb Nothnagle
University of Texas at Arlington, Fort Worth, TX
Search for other works by this author on:
Rita M. Patterson,
Rita M. Patterson
University of North Texas, Fort Worth, TX
Search for other works by this author on:
Nicoleta Bugnariu,
Nicoleta Bugnariu
University of North Texas, Fort Worth, TX
Search for other works by this author on:
Muthu B. J. Wijesundara
Muthu B. J. Wijesundara
University of Texas at Arlington, Fort Worth, TX
Search for other works by this author on:
Mahdi Haghshenas-Jaryani
University of Texas at Arlington, Fort Worth, TX
Caleb Nothnagle
University of Texas at Arlington, Fort Worth, TX
Rita M. Patterson
University of North Texas, Fort Worth, TX
Nicoleta Bugnariu
University of North Texas, Fort Worth, TX
Muthu B. J. Wijesundara
University of Texas at Arlington, Fort Worth, TX
Paper No:
DETC2017-68291, V003T13A005; 10 pages
Published Online:
November 3, 2017
Citation
Haghshenas-Jaryani, M, Nothnagle, C, Patterson, RM, Bugnariu, N, & Wijesundara, MBJ. "Soft Robotic Rehabilitation Exoskeleton (REHAB Glove) for Hand Therapy." Proceedings of the ASME 2017 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference. Volume 3: 19th International Conference on Advanced Vehicle Technologies; 14th International Conference on Design Education; 10th Frontiers in Biomedical Devices. Cleveland, Ohio, USA. August 6–9, 2017. V003T13A005. ASME. https://doi.org/10.1115/DETC2017-68291
Download citation file:
160
Views
Related Proceedings Papers
Related Articles
Dampace: Design of an Exoskeleton for Force-Coordination Training in Upper-Extremity Rehabilitation
J. Med. Devices (September,2009)
Wireless Vibrotactile Trainer for Balance Rehabilitation
J. Med. Devices (June,2009)
Related Chapters
Feedback-Aided Minimum Joint Motion
Robot Manipulator Redundancy Resolution
Manipulability-Maximizing SMP Scheme
Robot Manipulator Redundancy Resolution
Modeling and Realization on a Chip of Growth Hormone Secretion Mechanism
Intelligent Engineering Systems Through Artificial Neural Networks, Volume 17