Central venous catheterization (CVC) is a medical procedure where a surgeon attempts to place a catheter in the jugular, subclavian, or femoral vein. While useful, this procedure places patients at risk of a wide variety of adverse effects. Traditionally, training is performed on CVC mannequins, but these mannequins cannot vary patient anatomy. This work describes the development of a mobile training platform utilizing a haptic robotic arm and electromagnetic tracker to simulate a CVC needle insertion. A haptic robotic arm with custom syringe attachment used force feedback to provide the feeling of a needle insertion. A virtual ultrasound environment was created and made navigable by a mock ultrasound probe containing a magnetic tracking device. The effectiveness of the system as a training tool was tested on 12 medical students without CVC experience. An average increase in successful first insertion of 4.2% per practice scenario was seen in students who trained exclusively on the robotic training device. The robotic training device was able to successfully vary the difficulty of the virtual patient scenarios which in turn affected the success rates of the medical students. These results show that this system has the potential to successfully train medical residents for future CVC insertions.
Skip Nav Destination
ASME 2016 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference
August 21–24, 2016
Charlotte, North Carolina, USA
Conference Sponsors:
- Design Engineering Division
- Computers and Information in Engineering Division
ISBN:
978-0-7918-5015-2
PROCEEDINGS PAPER
Design of a Virtual Reality Haptic Robotic Central Venous Catheterization Training Simulator
David Pepley,
David Pepley
Pennsylvania State University, University Park, PA
Search for other works by this author on:
Mary Yovanoff,
Mary Yovanoff
Pennsylvania State University, University Park, PA
Search for other works by this author on:
Katelin Mirkin,
Katelin Mirkin
Penn State College of Medicine, Hershey, PA
Search for other works by this author on:
David Han,
David Han
Penn State College of Medicine, Hershey, PA
Search for other works by this author on:
Scarlett Miller,
Scarlett Miller
Pennsylvania State University, University Park, PA
Search for other works by this author on:
Jason Moore
Jason Moore
Pennsylvania State University, University Park, PA
Search for other works by this author on:
David Pepley
Pennsylvania State University, University Park, PA
Mary Yovanoff
Pennsylvania State University, University Park, PA
Katelin Mirkin
Penn State College of Medicine, Hershey, PA
David Han
Penn State College of Medicine, Hershey, PA
Scarlett Miller
Pennsylvania State University, University Park, PA
Jason Moore
Pennsylvania State University, University Park, PA
Paper No:
DETC2016-59560, V05AT07A033; 8 pages
Published Online:
December 5, 2016
Citation
Pepley, D, Yovanoff, M, Mirkin, K, Han, D, Miller, S, & Moore, J. "Design of a Virtual Reality Haptic Robotic Central Venous Catheterization Training Simulator." Proceedings of the ASME 2016 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference. Volume 5A: 40th Mechanisms and Robotics Conference. Charlotte, North Carolina, USA. August 21–24, 2016. V05AT07A033. ASME. https://doi.org/10.1115/DETC2016-59560
Download citation file:
31
Views
Related Proceedings Papers
Related Articles
A Virtual Reality Haptic Robotic Simulator for Central Venous Catheterization Training
J. Med. Devices (September,2016)
Weight Sensation in Virtual Environments Using a Haptic Device With Air Jets
J. Comput. Inf. Sci. Eng (June,2003)
Design and Evaluation of a Handheld Robotic Device for Peripheral Catheterization
J. Med. Devices (June,2022)
Related Chapters
Introduction and Scope
High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging
Occupational Risk and Health System Design Process
International Conference on Instrumentation, Measurement, Circuits and Systems (ICIMCS 2011)
Insights and Results of the Shutdown PSA for a German SWR 69 Type Reactor (PSAM-0028)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)