Pancreatic cancer is one of the most deadly forms of cancer in the United States. Due to its late diagnosis, only 20% of patients diagnosed with the disease are eligible for surgical resection which is considered the preferred method of treatment. Radiofrequency ablation is a common cancer treatment modality for patients ineligible for open surgery. There is a lack of ablation probes which may be used to generate spherical heating zones which closely match the geometry of typical tumors. In particular, there are no endoscopic ablation probes commercially available in the United States. In this paper the design of a compliant endoscopic radiofrequency ablation probe is presented. This probe features an array of compliant tines which deploy through the cancerous tissue to effectively broaden the ablation zone. A thermal ablation model is used to inform the design of the geometry of the probe. In addition, finite element analysis is used to determine the feasibility of the compliant structures. These design tools are used as aids to inform the design and direct modifications toward a feasible probe which generates a spherical ablation zone.
Skip Nav Destination
ASME 2016 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference
August 21–24, 2016
Charlotte, North Carolina, USA
Conference Sponsors:
- Design Engineering Division
- Computers and Information in Engineering Division
ISBN:
978-0-7918-5015-2
PROCEEDINGS PAPER
Design of a Compliant Endoscopic Ultrasound-Guided Radiofrequency Ablation Probe
Bradley W. Hanks,
Bradley W. Hanks
Pennsylvania State University, University Park, PA
Search for other works by this author on:
Mary Frecker,
Mary Frecker
Pennsylvania State University, University Park, PA
Search for other works by this author on:
Matthew Moyer
Matthew Moyer
Hershey Medical Center, Hershey, PA
Search for other works by this author on:
Bradley W. Hanks
Pennsylvania State University, University Park, PA
Mary Frecker
Pennsylvania State University, University Park, PA
Matthew Moyer
Hershey Medical Center, Hershey, PA
Paper No:
DETC2016-59923, V05AT07A022; 9 pages
Published Online:
December 5, 2016
Citation
Hanks, BW, Frecker, M, & Moyer, M. "Design of a Compliant Endoscopic Ultrasound-Guided Radiofrequency Ablation Probe." Proceedings of the ASME 2016 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference. Volume 5A: 40th Mechanisms and Robotics Conference. Charlotte, North Carolina, USA. August 21–24, 2016. V05AT07A022. ASME. https://doi.org/10.1115/DETC2016-59923
Download citation file:
21
Views
Related Articles
CT Visualization of Cryoablation in Pulmonary Veins
J. Med. Devices (June,2009)
Pre-Clinical Evaluation of Direct Current Ablation for the Treatment of Benign Prostatic Hyperplasia
J. Med. Devices (June,2009)
Optimization of an Endoscopic Radiofrequency Ablation Electrode
J. Med. Devices (September,2018)
Related Chapters
Experimental Studies
Nanoparticles and Brain Tumor Treatment
Introduction
Nanoparticles and Brain Tumor Treatment
Conclusion & executive summary
Photodynamic Therapy Mediated by Fullerenes and their Derivatives