A direct cardiac compression (DCC) device is an active sleeve that is surgically placed around the heart to help the failing heart to pump without contacting blood. Soft robotic techniques enable fabrication of a conformable DCC device containing modular actuators oriented in a biomimetic manner that can restore the natural motion of the heart and provide tunable active assistance. In this paper we describe the fabrication of a DCC device; the optimization of pneumatic actuators, their integration into a matrix with a modulus in the range of cardiac tissue and methods to affix this device to the heart wall. Pneumatic air muscles (PAMs) were fabricated using a modified McKibben technique and four types of internal bladders; low durometer silicone tubes molded in-house, polyester terephthalate (PET) heat shrink tubing, nylon medical balloons and thermoplastic urethane (TPU) balloons thermally formed in-house. Balloons were bonded to air supply lines, placed inside a braided nylon mesh with a 6.35mm resting diameter and bonded at one end. When pressurized to 145kPa silicone tubes failed and PET, nylon and TPU actuators generated isometric axial forces of 14.28, 19.65 and 19.05N respectively, with axial contractions of 33.11, 28.69 and 37.54%. Circumferential actuators placed around the heart reduced the cross-sectional area by 33.34% and 50.63% for silicone and TPU actuators respectively. PAMs were integrated into a soft matrix in a biomimetic orientation using three techniques; casting, thermal forming and layering. Designs were compared on an in vitro cardiac simulator and generated a volumetric displacement of up to 96ml when actuated for 200ms at 1Hz. Layering produced the lowest profile device that successfully conformed to the heart and this design is currently undergoing in vivo testing.
Skip Nav Destination
ASME 2015 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference
August 2–5, 2015
Boston, Massachusetts, USA
Conference Sponsors:
- Design Engineering Division
- Computers and Information in Engineering Division
ISBN:
978-0-7918-5712-0
PROCEEDINGS PAPER
Design and Fabrication of a Soft Robotic Direct Cardiac Compression Device
Ellen T. Roche,
Ellen T. Roche
Harvard University, Cambridge, MA
Search for other works by this author on:
Markus A. Horvath,
Markus A. Horvath
Harvard University, Cambridge, MA
Search for other works by this author on:
Ali Alazmani,
Ali Alazmani
Harvard University, Cambridge, MA
Search for other works by this author on:
Kevin C. Galloway,
Kevin C. Galloway
Harvard University, Cambridge, MA
Search for other works by this author on:
Nikolay V. Vasilyev,
Nikolay V. Vasilyev
Children’s Hospital Boston, Boston, MA
Search for other works by this author on:
David J. Mooney,
David J. Mooney
Harvard University, Cambridge, MA
Search for other works by this author on:
Frank A. Pigula,
Frank A. Pigula
Children’s Hospital Boston, Boston, MA
Search for other works by this author on:
Conor J. Walsh
Conor J. Walsh
Harvard University, Cambridge, MA
Search for other works by this author on:
Ellen T. Roche
Harvard University, Cambridge, MA
Markus A. Horvath
Harvard University, Cambridge, MA
Ali Alazmani
Harvard University, Cambridge, MA
Kevin C. Galloway
Harvard University, Cambridge, MA
Nikolay V. Vasilyev
Children’s Hospital Boston, Boston, MA
David J. Mooney
Harvard University, Cambridge, MA
Frank A. Pigula
Children’s Hospital Boston, Boston, MA
Conor J. Walsh
Harvard University, Cambridge, MA
Paper No:
DETC2015-47355, V05AT08A042; 10 pages
Published Online:
January 19, 2016
Citation
Roche, ET, Horvath, MA, Alazmani, A, Galloway, KC, Vasilyev, NV, Mooney, DJ, Pigula, FA, & Walsh, CJ. "Design and Fabrication of a Soft Robotic Direct Cardiac Compression Device." Proceedings of the ASME 2015 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference. Volume 5A: 39th Mechanisms and Robotics Conference. Boston, Massachusetts, USA. August 2–5, 2015. V05AT08A042. ASME. https://doi.org/10.1115/DETC2015-47355
Download citation file:
167
Views
Related Proceedings Papers
Related Articles
Development of A Medical Device for Quantitative Physical Therapies
J. Med. Devices (June,2008)
Miniaturized Cutting Tool With Triaxial Force Sensing Capabilities for Minimally Invasive Surgery
J. Med. Devices (September,2007)
Intra-Operative Pulse Oximetry
J. Med. Devices (June,2009)
Related Chapters
Concluding remarks
Mechanical Blood Trauma in Circulatory-Assist Devices
Introductory Survey
Introduction to Plastics Engineering
Process Components
Bioprocessing Piping and Equipment Design: A Companion Guide for the ASME BPE Standard