Cooling fans have been a critical part of the thermal management of commercial and military electronic equipment. Although accelerated testing by increasing operating temperatures has been commonly adopted in order to estimate the reliability of cooling fans in a short time frame, the testing time is usually more than 6 months due to the high reliability of current ball bearings. Prognostics and health management is a potential way to solve this problem. The first step in PHM is to identify precursor parameters. This article begins with the identification of precursor parameters from published studies and failure modes, mechanisms, and effects analysis (FMMEA). The health of cooling fans was estimated by monitoring three precursor parameters including acoustic noise, shaft rotational speed, and current consumption. Then the parameter value changes were compared to the failure criteria described in the IPC-9591 standard.
Skip Nav Destination
ASME 2009 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference
August 30–September 2, 2009
San Diego, California, USA
Conference Sponsors:
- Design Engineering Division and Computers in Engineering Division
ISBN:
978-0-7918-4899-9
PROCEEDINGS PAPER
Identification of Failure Precursor Parameters for Cooling Fans
Hyunseok Oh,
Hyunseok Oh
University of Maryland, College Park, MD
Search for other works by this author on:
Tadahiro Shibutani,
Tadahiro Shibutani
Yokohama National University, Yokohama, Kanagawa, Japan
Search for other works by this author on:
Michael Pecht
Michael Pecht
University of Maryland, College Park, MD; City University of Hong Kong, Hong Kong, China
Search for other works by this author on:
Hyunseok Oh
University of Maryland, College Park, MD
Tadahiro Shibutani
Yokohama National University, Yokohama, Kanagawa, Japan
Michael Pecht
University of Maryland, College Park, MD; City University of Hong Kong, Hong Kong, China
Paper No:
DETC2009-86280, pp. 1253-1258; 6 pages
Published Online:
July 29, 2010
Citation
Oh, H, Shibutani, T, & Pecht, M. "Identification of Failure Precursor Parameters for Cooling Fans." Proceedings of the ASME 2009 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference. Volume 2: 29th Computers and Information in Engineering Conference, Parts A and B. San Diego, California, USA. August 30–September 2, 2009. pp. 1253-1258. ASME. https://doi.org/10.1115/DETC2009-86280
Download citation file:
7
Views
Related Proceedings Papers
Related Articles
Computational aeroacoustics of low-pressure axial fans installed in parallel
J. Fluids Eng (January,0001)
Prediction and Measurement of Temperature Fields in Silicon-on-Insulator Electronic Circuits
J. Heat Transfer (August,1995)
Convection Cooling of Power Electronics Operating in Deep-Space
J. Electron. Packag (December,2024)
Related Chapters
Fans and Air Handling Systems
Thermal Management of Telecommunications Equipment
In Situ Observations of the Failure Mechanisms of Hydrided Zircaloy-4
Zirconium in the Nuclear Industry: 20th International Symposium
Introduction
Thermal Management of Microelectronic Equipment