Subsynchronous oscillation (SSO) or torsional vibration may cause shaft of steam turbine generator hurt heavily. This phenomenon has destroyed two generator shafts in one of China’s power plant in 2008. Detailed analysis and several measurements have been taken to identify the reason of the accident. First, the operational data is analyzed, including field torsional vibration dada. Then, the modal of the shaft system is calculated. Each torsional vibration frequency is gotten with corresponding modal shape. Dangerous location of the shaft system is obtained. Third, torque value of different operation condition is calculated based on two different models: one is traditional multiple mass element rotor dynamic model and the other is an four mass element electromechanical model of rotor oscillation. Following, the maximum stress on the dangerous location is calculated using finite element method. Finally, the root cause of shaft destruction is analyzed and identified.
Skip Nav Destination
ASME 2009 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference
August 30–September 2, 2009
San Diego, California, USA
Conference Sponsors:
- Design Engineering Division and Computers in Engineering Division
ISBN:
978-0-7918-4898-2
PROCEEDINGS PAPER
Torsional Vibration Analysis and Stress Calculation for the Fault 600MW Steam Turbine Generator Shaft System Available to Purchase
Dongxiang Jiang,
Dongxiang Jiang
Tsinghua University, Beijing, China
Search for other works by this author on:
Liangyou Hong,
Liangyou Hong
Tsinghua University, Beijing, China
Search for other works by this author on:
Zheng Wang,
Zheng Wang
Tsinghua University, Beijing, China
Search for other works by this author on:
Xiaorong Xie
Xiaorong Xie
Tsinghua University, Beijing, China
Search for other works by this author on:
Dongxiang Jiang
Tsinghua University, Beijing, China
Liangyou Hong
Tsinghua University, Beijing, China
Zheng Wang
Tsinghua University, Beijing, China
Xiaorong Xie
Tsinghua University, Beijing, China
Paper No:
DETC2009-86854, pp. 103-109; 7 pages
Published Online:
July 29, 2010
Citation
Jiang, D, Hong, L, Wang, Z, & Xie, X. "Torsional Vibration Analysis and Stress Calculation for the Fault 600MW Steam Turbine Generator Shaft System." Proceedings of the ASME 2009 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference. Volume 1: 22nd Biennial Conference on Mechanical Vibration and Noise, Parts A and B. San Diego, California, USA. August 30–September 2, 2009. pp. 103-109. ASME. https://doi.org/10.1115/DETC2009-86854
Download citation file:
26
Views
Related Proceedings Papers
Related Articles
Dynamics of Slant Cracked Rotor for a Steam Turbine Generator System
J. Eng. Gas Turbines Power (June,2017)
Dynamic Gear Loads Due to Coupled Lateral, Torsional and Axial Vibrations in a Helical Geared System
J. Vib. Acoust (April,1999)
An Investigation of Excitation Method for Torsional Testing of a Large-Scale Steam Turbine Generator
J. Vib. Acoust (January,2004)
Related Chapters
Vibration Analysis of the Seated Human Body in Vertical Direction
International Conference on Computer Technology and Development, 3rd (ICCTD 2011)
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies
Introduction
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration