Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Volume
- References
- Conference Volume
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Volume
- References
- Conference Volume
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Volume
- References
- Conference Volume
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Volume
- References
- Conference Volume
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Volume
- References
- Conference Volume
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Volume
- References
- Conference Volume
- Paper No
NARROW
Format
Article Type
Topics
Date
Availability
1-1 of 1
Keywords: VVER-440/213
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Proceedings Papers
Chester Everline, Gregory Gromov, Igor Lola, Stanislav Sholomitsky, Victor Mukoid, Steve Meyer, Alexander Sevbo
Proc. ASME. ICONE12, 12th International Conference on Nuclear Engineering, Volume 3, 177-184, April 25–29, 2004
Paper No: ICONE12-49342
... VVER-440/213 thermal hydraulic analysis LOCA Main Gate Valve closure operator actions The paper presents the results of the special screening assessment, conducted under the Level 1 Probabilistic Risk Assessment (PRA) study for the Rivne Nuclear Power Plant (RNPP) Unit 1, Ukraine. This...
Abstract
The paper presents the results of the special screening assessment, conducted under the Level 1 Probabilistic Risk Assessment (PRA) study for the Rivne Nuclear Power Plant (RNPP) Unit 1, Ukraine. This analysis has been intended to investigate potential for negative impacts of the closure of the Main Gate Valves (MGV) during loss of coolant accident (LOCA). RNPP Unit 1 is a VVER-440 Model 213 plant featuring six operating primary loops with MGVs installed at the hot and cold legs of each loop. Emergency operating instructions (EOIs) direct operators to isolate a leaking primary loop using the MGVs during a LOCA. From the experience of accident analyses for some Westinghouse plants it is known that closing loop stop valves (LSV, which are analogous to the VVER-440 MGVs) during accidents may result in more severe consequences. In particular, closing a LSV (or MGV) during a LOCA could inhibit steam venting through the break, and thus depress core levels. This would hasten the onset of core damage. Considering this experience, there has been a need to address such potential impacts in the RNPP Unit 1 PRA, taking into account design specifics of the VVER-440/213 plants. The analysis, which has combined qualitative considerations and thermal-hydraulic calculations with RELAP5/Mod3.2 model of the RNPP Unit 1 nuclear steam supply system, has revealed that such impacts are unimportant for this plant. The paper presents the approach and results of the assessment, and describes the supporting reactor thermal hydraulic evaluations.