A FLiNaK high temperature test loop, which was designed to support the Thorium Molten Salt Reactor (TMSR) program, was constructed in 2012 and is the largest engineering-scale fluoride loop in the world. The loop is built of Hastelloy C276 and is capable of operating at the flow rate up to 25m3/h and at the temperature up to 650°C. It consists of an overhung impeller sump-type centrifugal pump, an electric heater, a heat exchanger, a freeze valve and a mechanical one, a storage tank, etc. Salt purification was conducted in batch mode before it was transferred to and then stored in the storage tank. The facility was upgraded in three ways last year, with aims of testing a 30kW electric heater and supporting the heat transfer experiment in heat exchanger. Firstly, an original 100kW electric heater was replaced with a 335kW one to compensate the overlarge heat loss in the radiator. A pressure transmitter was subsequently installed in the inlet pipe of this updated heater. Finally, a new 30kW electric heater was installed between the pump and radiator, the purpose of which was to verify the core’s convective heat transfer behavior of a simulator design of TMSR. Immediately after these above works, shakedown test of the loop was carried out step by step. At first the storage tank was gradually preheated to 500°C so as to melt the frozen salt. Afterwards, in order to make the operation of transferring salt from storage tank to loop achievable, the loop system was also preheated to a relatively higher temperature 530°C. Since the nickel-base alloy can be severely corroded by the FLiNaK salt once the moisture and oxygen concentration is high, vacuum pumping and argon purging of the entire system were alternatively performed throughout the preheating process, with the effect of controlling them to be lower than 100ppm. Once the salt was transferred into the loop, the pump was immediately put into service. At the very beginning of operation process, it was found that flow rate in the main piping could not be precisely measured by the ultrasonic flow meter. Ten days later, the pump’s dry running gas seal was out of order. As a result, the loop had to be closed down to resolve these issues.
Skip Nav Destination
2018 26th International Conference on Nuclear Engineering
July 22–26, 2018
London, England
Conference Sponsors:
- Nuclear Engineering Division
ISBN:
978-0-7918-5143-2
PROCEEDINGS PAPER
Upgrade and Shakedown Test of a High Temperature Fluoride Salt Test Loop
Xiangbo Kong,
Xiangbo Kong
Chinese Academy of Science, Shanghai, China
Search for other works by this author on:
Yuan Fu,
Yuan Fu
Chinese Academy of Science, Shanghai, China
Search for other works by this author on:
Jianyu Zhang,
Jianyu Zhang
Chinese Academy of Science, Shanghai, China
Search for other works by this author on:
Huiju Lu,
Huiju Lu
Chinese Academy of Science, Shanghai, China
Search for other works by this author on:
Naxiu Wang
Naxiu Wang
Chinese Academy of Science, Shanghai, China
Search for other works by this author on:
Xiangbo Kong
Chinese Academy of Science, Shanghai, China
Yuan Fu
Chinese Academy of Science, Shanghai, China
Jianyu Zhang
Chinese Academy of Science, Shanghai, China
Huiju Lu
Chinese Academy of Science, Shanghai, China
Naxiu Wang
Chinese Academy of Science, Shanghai, China
Paper No:
ICONE26-81222, V001T13A004; 8 pages
Published Online:
October 24, 2018
Citation
Kong, X, Fu, Y, Zhang, J, Lu, H, & Wang, N. "Upgrade and Shakedown Test of a High Temperature Fluoride Salt Test Loop." Proceedings of the 2018 26th International Conference on Nuclear Engineering. London, England. July 22–26, 2018. V001T13A004. ASME. https://doi.org/10.1115/ICONE26-81222
Download citation file:
50
Views
Related Proceedings Papers
Related Articles
Development of High-Temperature Transport Technologies for Liquid Cadmium in Pyrometallurgical Reprocessing
J. Eng. Gas Turbines Power (July,2009)
On a General Method of Unsteady Potential Calculation Applied to the Compression Stages of a Turbomachine—Part II: Experimental Comparison
J. Fluids Eng (December,2001)
Performance Characteristics of a Thermosyphon Solar Domestic Hot Water System
J. Sol. Energy Eng (August,1981)
Related Chapters
Dynamic Behavior of Pumping Systems
Pipeline Pumping and Compression Systems: A Practical Approach
Subsection NCA—General Requirements for Division 1 and Division 2
Companion Guide to the ASME Boiler & Pressure Vessel Codes, Volume 1 Sixth Edition
Subsection NCA—General Requirements for Division 1 and Division 2
Companion Guide to the ASME Boiler & Pressure Vessel Code, Volume 1, Second Edition