Study of availability in radiation environment is presented for video monitoring system. Testing experiment has been completed by seven kinds of Image sensor module which includes three kinds of digital image sensor module and four kinds of analog image sensor module. Radiation accident condition was simulated by γ-ray ionizing radiation environment where the dose rate at 16.63Gy/h 20.20Gy/h and 58.30Gy/h. Availability has been studied by analyzing real time monitoring image quality parameters captured in γ-ray exposure environment. The primary image quality parameters include average gray level of the dark image and synthetic brightness of the color image. The most suitable image sensor module has been selected by image quality parameters for comparison before and after irradiation. Experimental results show that, digital camera has minimum background noise. The radiation resistance of CMOS image sensors is better than CCD image sensors. Therefore, digital video monitoring system with CMOS image sensor has the best image quality parameters and slightest effect in γ-ray ionizing radiation environment where the dose rate is less than 58.30Gy/h. Meanwhile, adequate light could reduce noise interference reduced by γ-ray for all types of video monitoring system. However, digital signal processing integrated circuit board has been destroyed when the accumulated dose reach to 88.40Gy, but the CMOS image sensor integrated circuit board has normal working parameters. As a conclusion, digital video monitoring system with CMOS image sensor could be used for real-time monitoring in radiation accident condition, but the digital signal processing integrated circuit board needs to be hardened by radiation hardened technology.
Skip Nav Destination
2016 24th International Conference on Nuclear Engineering
June 26–30, 2016
Charlotte, North Carolina, USA
Conference Sponsors:
- Nuclear Engineering Division
ISBN:
978-0-7918-5001-5
PROCEEDINGS PAPER
Video Monitoring System Availability in Radiation Accident Condition
Shou-long Xu,
Shou-long Xu
University of South China, HengYang, China
Search for other works by this author on:
Shu-liang Zou
Shu-liang Zou
University of South China, HengYang, China
Search for other works by this author on:
Shou-long Xu
University of South China, HengYang, China
Shu-liang Zou
University of South China, HengYang, China
Paper No:
ICONE24-60848, V001T04A015; 7 pages
Published Online:
October 25, 2016
Citation
Xu, S, & Zou, S. "Video Monitoring System Availability in Radiation Accident Condition." Proceedings of the 2016 24th International Conference on Nuclear Engineering. Charlotte, North Carolina, USA. June 26–30, 2016. V001T04A015. ASME. https://doi.org/10.1115/ICONE24-60848
Download citation file:
9
Views
Related Proceedings Papers
Related Articles
Applicability of the Dose Spiking Electron Paramagnetic Resonance Method for the Quantitative Measurements of Low Doses in Alanine Dosimetry
ASME J of Nuclear Rad Sci (January,2023)
The Use of Polycarbonate as Dosimeter of High Doses
ASME J of Nuclear Rad Sci (April,2021)
Models for Estimating Solar Radiation and Illuminance From Meteorological Parameters
J. Sol. Energy Eng (August,2000)
Related Chapters
Multi-Channel Constant Current LED Driver with PWM Boost Converter
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)
A 10GHz CMOS VCO with Low Phase Noise
Proceedings of the International Conference on Internet Technology and Security
4-Bit Pipeline ADC for Monolithic Active Pixel Sensors
International Conference on Advanced Computer Theory and Engineering (ICACTE 2009)