The automatic depressurization system (ADS) stage 4 valves inadvertent actuation scenario is one of the risk-significant cases in probabilistic risk assessment (PRA) analysis of passive power plant. Based on mini-ASTRUM (automated statistical treatment of uncertainty method) and CQD (code qualification document) method together, the calculation which utilizing WCOBRA/TRAC and HOTSPOT codes has been made in this paper. And the results indicate that, the calculated peak cladding temperature (PCT), local maximum oxidation (LMO), and core-wide oxidation (CWO) are all low enough, which meet the three design acceptance criteria defined in 10 CFR 50.46 emergency core cooling system (ECCS).

This content is only available via PDF.