Loss-of-pool-cooling accidents at the spent fuel pools in the reactor hall of a Nordic BWR have been studied using the MELCOR 1.8.6 code. Studies were made with several different calculation nodalizations. Other investigated variables were the total decay heat power of fuel assemblies in the pool, the initiator of the accident (loss of pool cooling or loss of coolant from the pool), the LOCA leak elevation, the alignment of the re-flooding injection and the use of a lid on top of the pool.

From the results it was observed that ensuring natural circulation of air in the fuel is essential in preventing fuel damages. In cases where the air flow is prevented (loss of pool cooling, LOCA break elevation above the bottom of fuel assemblies or a lid on top of the pool) the fuel is damaged in nearly all cases. Only with the pool decay power being sufficiently low (2227 kW) the melting of the fuel was prevented.

If water injection to the SFP can be restarted before the fuel temperature reaches the cladding failure criterion (1173 K), the rewetting of fuel assemblies is successful and the fuel temperatures will quickly decrease and the assemblies will remain intact. The re-flooding of already damaged fuel assemblies will also cool the fuel rods and reduce the radioactive releases to the environment. However, it may result in greater hydrogen releases.

This content is only available via PDF.