Developing the advanced nuclear power plant design to meet the demanding safety, efficiency and environmental goals of electric utilities requires great efforts. A passive emergency feedwater system (PEFS) combined with other passive engineering safety features (PESF) is introduced into PCWA (Passive Combined With Active) designs. The typical accidents are calculated and analyzed for this safety system design, especially steam generator tube rupture (SGTR). It is preliminarily concluded that this safety system design in PCWA makes a great balance between passive and active safety systems, and no radioactive liquid was released to the environment except some steam from affected steam generator.
Volume Subject Area:
Nuclear Safety and Security
Topics:
Accidents,
Boilers,
Design,
Emergencies,
Feedwater,
Nuclear design,
Public utilities,
Rupture,
Safety,
Steam
This content is only available via PDF.
Copyright © 2013 by ASME
You do not currently have access to this content.