According to the design features of the nuclear power plant in Taishan, a station blackout (SBO) at full power is a complex sequence, induced by the loss of offsite power (LOOP) combined with the loss of the emergency diesel generators (EDGs). This paper shall be performed the deterministic safety analysis of SBO without PSA study, and it mainly analyzes an overheating event of primary coolant resulting in the temporary unavailability of the steam generators (SGs) feeding systems during the station blackout. The analysis of this accident is carried out using the CATHARE2 thermal hydraulic code. The analysis pointed out that the final state can be reached after the operator performs the main manual actions such as startup of the SBO diesel generators from the main control room; startup of the two ASG pumps of trains 1 and 4; Local opening of the ASG header downstream the ASG pumps to enable the two power supplied ASG pumps to feed all the four SGs; initiation of a manual cooldown via the VDA in order to ensure the long term protection of the RCP pumps seals with respect to the thermal and mechanical loads. It corresponds to the achievement of a stable heat removal conditions by the emergency feedwater system (ASG) and the atmospheric steam dump system (VDA).
Skip Nav Destination
2013 21st International Conference on Nuclear Engineering
July 29–August 2, 2013
Chengdu, China
Conference Sponsors:
- Nuclear Engineering Division
ISBN:
978-0-7918-5578-2
PROCEEDINGS PAPER
Study of Station Blackout Accident Process in Taishan Nuclear Power Plant Available to Purchase
Huiyong Zhang,
Huiyong Zhang
CNPRI, Shenzhen, Guangdong, China
Search for other works by this author on:
Yehong Liao,
Yehong Liao
CNPRI, Shenzhen, Guangdong, China
Search for other works by this author on:
Dekui Zhan
Dekui Zhan
CNPRI, Shenzhen, Guangdong, China
Search for other works by this author on:
Yu Li
CNPRI, Shenzhen, Guangdong, China
Huiyong Zhang
CNPRI, Shenzhen, Guangdong, China
Yehong Liao
CNPRI, Shenzhen, Guangdong, China
Jiming Lin
CNPRI, Shenzhen, Guangdong, China
Dekui Zhan
CNPRI, Shenzhen, Guangdong, China
Paper No:
ICONE21-16214, V001T01A031; 6 pages
Published Online:
February 7, 2014
Citation
Li, Y, Zhang, H, Liao, Y, Lin, J, & Zhan, D. "Study of Station Blackout Accident Process in Taishan Nuclear Power Plant." Proceedings of the 2013 21st International Conference on Nuclear Engineering. Volume 1: Plant Operations, Maintenance, Engineering, Modifications, Life Cycle and Balance of Plant; Nuclear Fuel and Materials; Radiation Protection and Nuclear Technology Applications. Chengdu, China. July 29–August 2, 2013. V001T01A031. ASME. https://doi.org/10.1115/ICONE21-16214
Download citation file:
16
Views
Related Proceedings Papers
Related Articles
External Hazard Coinciding With Small Break LOCA—Thermohydraulic Calculation With System Code ATHLET
ASME J of Nuclear Rad Sci (April,2020)
Methodology for Calculating Minor Radioactive Releases From VVER 1000 Using TRACE Code
ASME J of Nuclear Rad Sci (April,2021)
Analyses of Feedwater Trip With SBO Sequence of VVER1000 Reactor
ASME J of Nuclear Rad Sci (October,2016)
Related Chapters
Insights and Results of the Shutdown PSA for a German SWR 69 Type Reactor (PSAM-0028)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
A PSA Update to Reflect Procedural Changes (PSAM-0217)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
Lessons Learned: NRC Experience
Continuing and Changing Priorities of the ASME Boiler & Pressure Vessel Codes and Standards