Reinforced concrete wall subjected to an impact by a hard steel missile with a mass of 47 kg and an impact velocity of 135 m/s was one case study in the IRIS 2010 benchmark exercise in OECD/NEA/CSNI/IAGE framework. The wall had dimensions of 2m × 2m × 0.25m and it was simply supported. The perforation of the missile was expected.

Fortum Power and Heat Ltd. participated in the benchmark. In this paper, we present our modeling and blind prediction of the benchmark case. The test results of the benchmark were released after the predictions were made.

Based on the result comparison, we concluded that our model gave conservative results.