Digital radiography is getting one of the common radiographic testing techniques in various industries now. However, to apply this new technique to nuclear components radiographic testing, one big issue is how we can evaluate and ensure that the taken images have enough image qualities to be used as inspection record. In film radiography, the IQI, which stands for Image Quality Indicator, have been used to ensure that taken films have enough quality to detect any specified defects in the products. So in this paper, new alternative IQI that developed in our previous study for digital radiography to evaluate digital image quality are tested and evaluated. In addition, image evaluation criteria are also developed and evaluated by calculating MTF, which stands for Modulation Transfer Function, from the IQI images taken with the products. Finally, the recommended procedures to evaluate radiographic testing image are summarized.
Skip Nav Destination
18th International Conference on Nuclear Engineering
May 17–21, 2010
Xi’an, China
Conference Sponsors:
- Nuclear Engineering Division
ISBN:
978-0-7918-4929-3
PROCEEDINGS PAPER
Digital Image Evaluation Method for Digital Radiography
Masako Mori,
Masako Mori
Hitachi-GE Nuclear Energy, Ltd., Hitachi, Japan
Search for other works by this author on:
Toshibumi Kashiwa,
Toshibumi Kashiwa
Hitachi-GE Nuclear Energy, Ltd., Hitachi, Japan
Search for other works by this author on:
Yoshimitsu Aoki
Yoshimitsu Aoki
Keio University, Yokohama, Japan
Search for other works by this author on:
Masako Mori
Hitachi-GE Nuclear Energy, Ltd., Hitachi, Japan
Toshibumi Kashiwa
Hitachi-GE Nuclear Energy, Ltd., Hitachi, Japan
Yoshimitsu Aoki
Keio University, Yokohama, Japan
Paper No:
ICONE18-29702, pp. 223-228; 6 pages
Published Online:
April 8, 2011
Citation
Mori, M, Kashiwa, T, & Aoki, Y. "Digital Image Evaluation Method for Digital Radiography." Proceedings of the 18th International Conference on Nuclear Engineering. 18th International Conference on Nuclear Engineering: Volume 1. Xi’an, China. May 17–21, 2010. pp. 223-228. ASME. https://doi.org/10.1115/ICONE18-29702
Download citation file:
9
Views
Related Proceedings Papers
Related Articles
F110-GE-132: Enhanced Power Through Low-Risk Derivative Technology
J. Turbomach (July,2001)
High-Speed Inspection of Rails by Passive Ultrasonic Monitoring
ASME J Nondestructive Evaluation (November,2022)
Related Chapters
IWE and IWL
Companion Guide to the ASME Boiler and Pressure Vessel Codes, Volume 2, Fifth Edition
Examination, Inspection, and Testing
Bioprocessing Piping and Equipment Design: A Companion Guide for the ASME BPE Standard
Design, Construction, Inspection and Testing of Containment Structures
Containment Structures of U.S. Nuclear Power Plants: Background, Regulations, Codes and Standards, and Other Considerations