The paper deals with the calculation of differential pressure on sieves after a loss of coolant accident (LOCA) in boiling water reactors. One of the main features in reactor safety research is the safe heat dissipation from the reactor core and the reactor containment of light-water reactors. In the case of loss of coolant accident the possibility of the entry of insulation material into the reactor containment and the building sump of the reactor containment and into the associated systems to the residual heat exhaust is a serious problem. This can lead to a handicap of the system functions. To ensure the residual heat exhaust it is necessary the emergency cooling systems to put in operation which transport the water from the sump to the condensation chamber and directly to the reactor pressure vessel. A high allocation of the sieves with fractionated insulation material, in the sump can lead to a blockage of the sieves, inadmissibly increase of differential pressure, build-up at the sieves and to malfunctioning pumps. Hence, the scaling and retention of fractionated insulation material in the building sump of the reactor containment must be estimated. This allows the potential plant status in case of incidents to be assessed. The differential pressure is the essential parameter for the assessment of allocation of the sieves.
Skip Nav Destination
17th International Conference on Nuclear Engineering
July 12–16, 2009
Brussels, Belgium
Conference Sponsors:
- Nuclear Engineering Division
ISBN:
978-0-7918-4352-9
PROCEEDINGS PAPER
Closed Model for Calculation of Differential Pressure After a Loss of Coolant Accident in Boiling Water Reactors
Alexander Kratzsch,
Alexander Kratzsch
University of Applied Sciences Zittau/Goerlitz, Zittau, Germany
Search for other works by this author on:
Wolfgang Ka¨stner,
Wolfgang Ka¨stner
University of Applied Sciences Zittau/Goerlitz, Zittau, Germany
Search for other works by this author on:
Rainer Hampel
Rainer Hampel
University of Applied Sciences Zittau/Goerlitz, Zittau, Germany
Search for other works by this author on:
Alexander Kratzsch
University of Applied Sciences Zittau/Goerlitz, Zittau, Germany
Wolfgang Ka¨stner
University of Applied Sciences Zittau/Goerlitz, Zittau, Germany
Rainer Hampel
University of Applied Sciences Zittau/Goerlitz, Zittau, Germany
Paper No:
ICONE17-75562, pp. 623-628; 6 pages
Published Online:
February 25, 2010
Citation
Kratzsch, A, Ka¨stner, W, & Hampel, R. "Closed Model for Calculation of Differential Pressure After a Loss of Coolant Accident in Boiling Water Reactors." Proceedings of the 17th International Conference on Nuclear Engineering. Volume 2: Structural Integrity; Safety and Security; Advanced Applications of Nuclear Technology; Balance of Plant for Nuclear Applications. Brussels, Belgium. July 12–16, 2009. pp. 623-628. ASME. https://doi.org/10.1115/ICONE17-75562
Download citation file:
6
Views
Related Proceedings Papers
Related Articles
The Plant Feature and Performance of Double MS (Modular Simplified and Medium Small Reactor)
J. Eng. Gas Turbines Power (January,2010)
External Hazard Coinciding With Small Break LOCA—Thermohydraulic Calculation With System Code ATHLET
ASME J of Nuclear Rad Sci (April,2020)
Quantitative and Qualitative Comparison of Light Water and Advanced Small Modular Reactors
ASME J of Nuclear Rad Sci (October,2015)
Related Chapters
Insights and Results of the Shutdown PSA for a German SWR 69 Type Reactor (PSAM-0028)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
Lessons Learned: NRC Experience
Continuing and Changing Priorities of the ASME Boiler & Pressure Vessel Codes and Standards
Modeling of SAMG Operator Actions in Level 2 PSA (PSAM-0164)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)