An electrical cable condition monitoring (CCM) method utilizing conductive polymer age sensors provides a distributed, in-situ approach that reduces access considerations and eliminates destructive testing, increasing safety by monitoring areas otherwise impractical or impossible. It reduces the cost of Generation IV cable condition monitoring by eliminating sample-retrieval and significantly reducing testing costs associated with conventional mechanical and chemical condition monitoring. Future applications include simple, lowcost condition monitoring of virtually any polymer used in industry, transportation, construction and recreation. The proposed CCM method utilizes inert conductive particles compounded with candidate insulation materials to provide an age “sensor” distributed in the wire or cable insulation or jacket. A simple electrical measurement, the resistivity of the sensor, correlates age-related degradation of mechanical properties such as elongation at break (EAB) and provides a means to determine remaining life of the insulation material. This paper summarizes the results of research being conducted under a DOE Small Business Innovative Research grant in concert with the School of Materials Science and Engineering at Georgia Tech and Rockbestos-Surprenant Cable Corp.
Skip Nav Destination
12th International Conference on Nuclear Engineering
April 25–29, 2004
Arlington, Virginia, USA
Conference Sponsors:
- Nuclear Engineering Division
ISBN:
0-7918-4687-3
PROCEEDINGS PAPER
An Electrical Condition Monitoring Approach for Wire and Cable Available to Purchase
Kenneth S. Watkins, Jr.,
Kenneth S. Watkins, Jr.
Polymer Aging Concepts, Inc., Dahlonega, GA
Search for other works by this author on:
Shelby J. Morris, Jr.,
Shelby J. Morris, Jr.
Polymer Aging Concepts, Inc., Dahlonega, GA
Search for other works by this author on:
C. P. Wong,
C. P. Wong
Georgia Institute of Technology, Atlanta, GA
Search for other works by this author on:
Lianhua Fan,
Lianhua Fan
Georgia Institute of Technology, Atlanta, GA
Search for other works by this author on:
Yang Yang Sun,
Yang Yang Sun
Georgia Institute of Technology, Atlanta, GA
Search for other works by this author on:
Daniel D. Masakowski,
Daniel D. Masakowski
Rockbestos Surprenant Cable Corporation
Search for other works by this author on:
Wendy Alvis
Wendy Alvis
JH Technology, Inc.
Search for other works by this author on:
Kenneth S. Watkins, Jr.
Polymer Aging Concepts, Inc., Dahlonega, GA
Shelby J. Morris, Jr.
Polymer Aging Concepts, Inc., Dahlonega, GA
C. P. Wong
Georgia Institute of Technology, Atlanta, GA
Lianhua Fan
Georgia Institute of Technology, Atlanta, GA
Yang Yang Sun
Georgia Institute of Technology, Atlanta, GA
Daniel D. Masakowski
Rockbestos Surprenant Cable Corporation
Wendy Alvis
JH Technology, Inc.
Paper No:
ICONE12-49559, pp. 169-174; 6 pages
Published Online:
November 17, 2008
Citation
Watkins, KS, Jr., Morris, SJ, Jr., Wong, CP, Fan, L, Sun, YY, Masakowski, DD, & Alvis, W. "An Electrical Condition Monitoring Approach for Wire and Cable." Proceedings of the 12th International Conference on Nuclear Engineering. 12th International Conference on Nuclear Engineering, Volume 1. Arlington, Virginia, USA. April 25–29, 2004. pp. 169-174. ASME. https://doi.org/10.1115/ICONE12-49559
Download citation file:
9
Views
Related Proceedings Papers
Related Articles
Rotor Condition Monitoring for Improved Operational Safety of Offshore Wind Energy Converters
J. Sol. Energy Eng (May,2005)
Computational and Experimental Mechanics of Advanced Materials
J. Eng. Mater. Technol (January,2003)
Diagnostics and Life-Cycle Assessment of Medium-Voltage Cables in Nuclear Power Plants During Regular Overhaul Process
ASME J of Nuclear Rad Sci (October,2016)
Related Chapters
Expert Systems in Condition Monitoring
Tribology of Mechanical Systems: A Guide to Present and Future Technologies
Research and Development of On-Line Partial Discharge Monitroevg Deveices on Medium Voltage Power Equipment
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
Testing the Drift Reduction Potential of Some Adjuvants from Renewable Sources for Aerial Pesticide Applications
Pesticide Formulation and Delivery Systems: 43rd Volume, Creating Certainty in an Uncertain World