The Tihange2 900 MWe 3-L PWR NPP, operated by the Belgian utility Electrabel, was first commissioned in 1982 with a design core power of 2775 MWth. Following an initial core power uprating by 4,5% in 1995, Electrabel has since replaced the Steam Generators which has allowed a further core power increase by roughly 5% (total 10%) in 2001. For both of each projects, licensing and implementation studies were successfully performed by Tractebel Energy Engineering and Framatome ANP. The demanding new operating conditions required a complete review of the plant design basis for which advanced methods were applied and licensed through a continuous process of discussions with the client and the Belgian Safety Authorities AVN. The licensing process required flexibility in the methods application in order to meet the specific requirements of the S.A., which was achieved within the time schedule and without jeopardising the technical objectives of the utility.
Skip Nav Destination
10th International Conference on Nuclear Engineering
April 14–18, 2002
Arlington, Virginia, USA
Conference Sponsors:
- Nuclear Engineering Division
ISBN:
0-7918-3596-0
PROCEEDINGS PAPER
Steam Generator Replacement and Power Uprating on Tihange 2 Nuclear Plant: Safety Study Analyses
Andre´ Malaval,
Andre´ Malaval
Framatome ANP, Paris-la De´fense, France
Search for other works by this author on:
Pascale Marin-Lafle`che,
Pascale Marin-Lafle`che
Framatome ANP, Paris-la De´fense, France
Search for other works by this author on:
Myriam Forgeot d’Arc,
Myriam Forgeot d’Arc
Framatome ANP, Paris-la De´fense, France
Search for other works by this author on:
Ce´line Collin
Ce´line Collin
Framatome ANP, Paris-la De´fense, France
Search for other works by this author on:
Andre´ Malaval
Framatome ANP, Paris-la De´fense, France
Pascale Marin-Lafle`che
Framatome ANP, Paris-la De´fense, France
Myriam Forgeot d’Arc
Framatome ANP, Paris-la De´fense, France
Ce´line Collin
Framatome ANP, Paris-la De´fense, France
Paper No:
ICONE10-22263, pp. 159-164; 6 pages
Published Online:
March 4, 2009
Citation
Malaval, A, Marin-Lafle`che, P, Forgeot d’Arc, M, & Collin, C. "Steam Generator Replacement and Power Uprating on Tihange 2 Nuclear Plant: Safety Study Analyses." Proceedings of the 10th International Conference on Nuclear Engineering. 10th International Conference on Nuclear Engineering, Volume 2. Arlington, Virginia, USA. April 14–18, 2002. pp. 159-164. ASME. https://doi.org/10.1115/ICONE10-22263
Download citation file:
8
Views
Related Proceedings Papers
Related Articles
Improving Nuclear Power Plant's Operational Efficiencies in the U.S.A.
Mechanical Engineering (January,2011)
Last Stage Performance Considerations in Low-Pressure Turbines of Power Plants: A Case Study
J. Eng. Gas Turbines Power (March,2008)
Hydrogen Peroxide-Based Gas Generator Design and Performance Testing as an Aircraft Emergency Power Unit
J. Eng. Gas Turbines Power (November,2010)
Related Chapters
Lessons Learned: NRC Experience
Continuing and Changing Priorities of the ASME Boiler & Pressure Vessel Codes and Standards
Development of Nuclear Boiler and Pressure Vessels in Taiwan
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 3, Third Edition
Fatigue Verification and Nonlinear Alternatives
Toward Consistent Design Evaluation of Nuclear Power Piping by Nonlinear Finite Element Analysis