In resource-limited settings, it is impractical to get access to a diagnostic laboratory having sophisticated instruments, and it is desirable to use disposable point-of-care diagnostic chips that do not require liquid handling or pumping instruments for sample distribution among an array of reactors. In addition to the pump-less sample loading method, the challenge to seal an array of reactors without the use of microvalves or mechanical parts still persists. Implementation of microvalve array adds complexity to the chip fabrication and operation processes, and also reduces the space on the microchip. In this paper, we report the development of a high-throughput quantitative PCR chip platform for parallel analyses of multiple gene targets. The PCR mixture distribution among an array of 80 microreactors and subsequent isolation of the reactors were solely realized by a two-step surface tension-based microfluidic scheme, which eliminates the use of pumps, valves and liquid handling instruments. Confinement of the PCR mixture inside the micro reactors was achieved by implementing hybrid flow-restriction passive valves. The microreactors were isolated from each other by the flow of a curable liquid sealant delivered through microchannels by capillary action. We also investigated the effect of detergents that are present in most commercial PCR buffers. Presence of detergents makes the PCR buffer much more wetting on the passive capillary valve surface and this imposes another challenge to the design of the conventional hydrophobic patch valves which has been successfully used for deionized water. We demonstrated a successful capillary valve array with a common air venting channel having a hydrophobic surface for restricting the flow of PCR buffer containing surfactant. The interconnected microreactor array was fabricated on a glass chip substrate with approximate volume of 250 nl microreactor volume for PCR. A different set of PCR primers were preloaded into different microreactor on the PCR array chip for simultaneous amplification of multiple genes. Fluorescent signals from all the microreactors were simultaneously detected at every PCR thermal cycle using EvaGreen fluorescent dye on an in-house real-time PCR instrument. The capability of the scalable PCR array chip was demonstrated by amplifying a fragment of uidA gene for beta-glucuronidase of E. coli genome. Key technical issues related to chip operation such as PCR inhibition on the acid-washed glass substrate, and PCR compatibility of the sealant in both the uncured and cured states have been addressed.
Skip Nav Destination
ASME 2009 7th International Conference on Nanochannels, Microchannels, and Minichannels
June 22–24, 2009
Pohang, South Korea
Conference Sponsors:
- Nanotechnology Institute
ISBN:
978-0-7918-4349-9
PROCEEDINGS PAPER
A Surface-Directed Microfluidic Scheme for Parallel Nanoliter PCR Array Suitable for Point-of-Care Testing
Naveen Ramalingam,
Naveen Ramalingam
Nanyang Technological University, Singapore
Search for other works by this author on:
Long-Qing Chen,
Long-Qing Chen
Nanyang Technological University, Singapore
Search for other works by this author on:
Xin-Hao Yang,
Xin-Hao Yang
Nanyang Technological University, Singapore
Search for other works by this author on:
Liqun Deng,
Liqun Deng
Nanyang Technological University, Singapore
Search for other works by this author on:
Qing-Hui Wang,
Qing-Hui Wang
Nanyang Technological University, Singapore
Search for other works by this author on:
Eric Yap Peng Huat,
Eric Yap Peng Huat
Defense Medical and Environmental Research Institute, Singapore
Search for other works by this author on:
Chiew Hoon Neo,
Chiew Hoon Neo
Nanyang Technological University, Singapore
Search for other works by this author on:
Hai-Qing Gong
Hai-Qing Gong
Nanyang Technological University, Singapore
Search for other works by this author on:
Naveen Ramalingam
Nanyang Technological University, Singapore
Long-Qing Chen
Nanyang Technological University, Singapore
Xin-Hao Yang
Nanyang Technological University, Singapore
Liqun Deng
Nanyang Technological University, Singapore
Qing-Hui Wang
Nanyang Technological University, Singapore
Eric Yap Peng Huat
Defense Medical and Environmental Research Institute, Singapore
Chiew Hoon Neo
Nanyang Technological University, Singapore
Hai-Qing Gong
Nanyang Technological University, Singapore
Paper No:
ICNMM2009-82052, pp. 1007-1013; 7 pages
Published Online:
September 21, 2010
Citation
Ramalingam, N, Chen, L, Yang, X, Deng, L, Wang, Q, Huat, EYP, Neo, CH, & Gong, H. "A Surface-Directed Microfluidic Scheme for Parallel Nanoliter PCR Array Suitable for Point-of-Care Testing." Proceedings of the ASME 2009 7th International Conference on Nanochannels, Microchannels, and Minichannels. ASME 2009 7th International Conference on Nanochannels, Microchannels and Minichannels. Pohang, South Korea. June 22–24, 2009. pp. 1007-1013. ASME. https://doi.org/10.1115/ICNMM2009-82052
Download citation file:
7
Views
Related Proceedings Papers
Related Articles
Optical Investigation Into Wall Wetting From Late-Cycle Post-Injections Used for Diesel Particulate Filter Regeneration
J. Eng. Gas Turbines Power (September,2011)
Use of Bacterial Carpets to Enhance Mixing in Microfluidic Systems
J. Fluids Eng (March,2007)
Development of Hermetic Microminiature Connectors
J. Electron. Packag (December,1991)
Related Chapters
Section III: Subsections NC and ND — Class 2 and 3 Components
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 1, Third Edition
Subsection NC, ND—Class 2 and 3 Components
Companion Guide to the ASME Boiler & Pressure Vessel Code, Volume 1, Second Edition
Process Components
Bioprocessing Piping and Equipment Design: A Companion Guide for the ASME BPE Standard