This study examines the refrigerant distribution of a dual cold plate system subject to the influence of heating load using a R-134a based vapor compression system with a nominal capacity ranging from 50∼250 W. The cold plate is of identical configuration. Initially, test is performed under an equal heating load for each cold plate (70 W) which then gives rise to a uniform distribution and equal outlet superheat condition. For an unequal heating load, it is found that the distribution of mass flowrate subject to the influence of heating load is strongly related to the outlet states of the two cold plates. For the condition where one of the cold plate is in superheated state while the other is in saturated state, the mass flowrate for the fixed heating load is lower than that of smaller heating load, and the difference increases when the heating load gets smaller due to the influence of accelerational pressure drop. A maximum of 17% difference is seen at a loading ratio of 0.571 (40W/70W). For the condition where both outlet states of cold plate are at superheated states, the mass flowrate for the fixed heating load is marginally higher than that of the smaller heating load, and the difference is insensitive to the rise of heating load. For this situation, the effect of accelerational pressure is negligible, and it is mainly attributed to two-phase/single-phase distribution pertaining to the effect of heating load.
Skip Nav Destination
ASME 2008 6th International Conference on Nanochannels, Microchannels, and Minichannels
June 23–25, 2008
Darmstadt, Germany
Conference Sponsors:
- Nanotechnology Institute
ISBN:
0-7918-4834-5
PROCEEDINGS PAPER
Influence of Variable Heat Load on the Refrigerant Distribution of a Dual Cold-Plate System
Chi-Chuan Wang
Chi-Chuan Wang
ITRI, Hsinchu, Taiwan
Search for other works by this author on:
Kai-Shing Yang
ITRI, Hsinchu, Taiwan
Kun-Huang Yu
ITRI, Hsinchu, Taiwan
Chung-Che Liu
ITRI, Hsinchu, Taiwan
Chi-Chuan Wang
ITRI, Hsinchu, Taiwan
Paper No:
ICNMM2008-62348, pp. 1431-1435; 5 pages
Published Online:
June 11, 2009
Citation
Yang, K, Yu, K, Liu, C, & Wang, C. "Influence of Variable Heat Load on the Refrigerant Distribution of a Dual Cold-Plate System." Proceedings of the ASME 2008 6th International Conference on Nanochannels, Microchannels, and Minichannels. ASME 2008 6th International Conference on Nanochannels, Microchannels, and Minichannels. Darmstadt, Germany. June 23–25, 2008. pp. 1431-1435. ASME. https://doi.org/10.1115/ICNMM2008-62348
Download citation file:
3
Views
Related Proceedings Papers
Related Articles
The Electro-Adsorption Chiller: Performance Rating of a Novel Miniaturized Cooling Cycle for Electronics Cooling
J. Heat Transfer (September,2006)
Effect of Variable Heating Load on the Refrigerant Distribution of a Dual Cold-Plate System
J. Electron. Packag (June,2009)
Thermal-Structural Performance of Orthotropic Pin Fin in Electronics Cooling Applications
J. Electron. Packag (December,2012)
Related Chapters
A Dependable Answer
Hot Air Rises and Heat Sinks: Everything You Know about Cooling Electronics Is Wrong
The Special Characteristics of Closed-Cycle Gas Turbines
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Thermoelectric Coolers
Thermal Management of Microelectronic Equipment