In this paper an experimental study was performed for relation between two-phase pressure drop and flow distribution in compact heat exchanger using small diameter tubes. We performed the experimental study in non-heating mode. A test section was consisted of the horizontal header (circular tube: φ 5 mm × 80 mm) and 10 upward circular channels (φ 1.5 mm × 850 mm) using acrylic tube. Three different types of tube insertion depth were tested for the mass flux and inlet quality ranging from of 50–200 kg/m2s and 0.1–0.3, respectively. Air and water were used as the test fluids. Two-phase pressure drop of each channel and three type of distribution header was measured. As whole, single-phase and two-phase, pressure drop in rear channel is found to be lower than that in front channel. In conclusion, we can claim that principle of distribution is almost same pressure drop in each channel. Comparing pressure drop in branch tube with correlation equation, it was found that in single-phase flow, experimental value was 10% lower than Hagen-Poiseuille, Blasius equation (Eq. 40) in two-phase flow.
Skip Nav Destination
ASME 2004 2nd International Conference on Microchannels and Minichannels
June 17–19, 2004
Rochester, New York, USA
Conference Sponsors:
- Nanotechnology Institute
ISBN:
0-7918-4164-2
PROCEEDINGS PAPER
A Relation Between Two-Phase Pressure Drop and Flow Distribution in a Compact Heat Exchanger Header
Jong-Soo Kim,
Jong-Soo Kim
Pukyong National University, Yongdangdong, Busan, Korea
Search for other works by this author on:
Ki-Taek Lee,
Ki-Taek Lee
Pukyong National University, Yongdangdong, Busan, Korea
Search for other works by this author on:
Jae-Hong Kim,
Jae-Hong Kim
Pukyong National University, Yongdangdong, Busan, Korea
Search for other works by this author on:
Soo-Jung Ha,
Soo-Jung Ha
Pukyong National University, Yongdangdong, Busan, Korea
Search for other works by this author on:
Yong-Bin Im
Yong-Bin Im
Pukyong National University, Yongdangdong, Busan, Korea
Search for other works by this author on:
Jong-Soo Kim
Pukyong National University, Yongdangdong, Busan, Korea
Ki-Taek Lee
Pukyong National University, Yongdangdong, Busan, Korea
Jae-Hong Kim
Pukyong National University, Yongdangdong, Busan, Korea
Soo-Jung Ha
Pukyong National University, Yongdangdong, Busan, Korea
Yong-Bin Im
Pukyong National University, Yongdangdong, Busan, Korea
Paper No:
ICMM2004-2363, pp. 413-420; 8 pages
Published Online:
December 2, 2008
Citation
Kim, J, Lee, K, Kim, J, Ha, S, & Im, Y. "A Relation Between Two-Phase Pressure Drop and Flow Distribution in a Compact Heat Exchanger Header." Proceedings of the ASME 2004 2nd International Conference on Microchannels and Minichannels. ASME 2nd International Conference on Microchannels and Minichannels. Rochester, New York, USA. June 17–19, 2004. pp. 413-420. ASME. https://doi.org/10.1115/ICMM2004-2363
Download citation file:
9
Views
Related Proceedings Papers
Related Articles
Modeling of Two-Phase Heat Exchangers With Zeotropic Fluid Mixtures
J. Heat Transfer (May,2018)
A Robust Asymptotically Based Modeling Approach for Two-Phase Flow in Porous Media
J. Heat Transfer (October,2009)
Prandtl Number Influence on Heat Transfer Enhancement in Turbulent Flow of Water at Low Temperatures
J. Heat Transfer (May,1995)
Related Chapters
Threshold Functions
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Adding Surface While Minimizing Downtime
Heat Exchanger Engineering Techniques
The Special Characteristics of Closed-Cycle Gas Turbines
Closed-Cycle Gas Turbines: Operating Experience and Future Potential