Data published elsewhere (Moore, et al., 1992; Bergman et al., 1997) suggests that the then costs of disposable type Glass Fibre HEPA filtration trains to the DOE was $55million per year (based on an average usage of HEPA panels of 11,748 pieces per year between 1987 and 1990), $50million of which was attributable to installation, testing, removal and disposal. The same authors suggest that by 1995 the number of HEPA panels being used had dropped to an estimated 4000 pieces per year due to the ending of the Cold War. The yearly cost to the DOE of 4000 units per year was estimated to be $29.5 million using the same parameters that previously suggested the $55 million figure. Within that cost estimate, $300 each was the value given to the filter and $4,450 was given to peripheral activity per filter. Clearly, if the $4,450 component could be reduced, tremendous saving could result, in addition to a significant reduction in the legacy burden of waste volumes. This same cost is applied to both the 11,748 and 4000 usage figures. The work up to now has focussed on the development of a low cost, long life (cleanable), direct replacement of the traditional filter train. This paper will review an alternative strategy, that of preventing the contaminating dust from reaching and blinding the HEPA filters, and thereby removing the need to replace them. What has become clear is that ‘low cost’ and ‘Metallic HEPA’ are not compatible terms. The original Bergman et al., 1997 work suggested that 1000 cfm (cubic feet per minute) (1690 m3/hr) stainless HEPAs could be commercially available for $5000 each after development (although the $70,000 development unit may be somewhat exaggerated – the authors own company have estimated development units able to be retrofitted into strengthened standard housings would be available for perhaps $30,000). The likely true cost of such an item produced industrially in significant numbers may be closer to $15,000 each. That being the case, the economics for replacing glass fibre HEPAs with the metallic, cleanable alternative are unjustifiable except on ethical grounds. By proposing the protection of the traditional Glass Fibre HEPA from its blinding contamination, a means is presented to reduce both their life costs and ultimate waste volumes. An examination of the case for self-cleaning HEPA protection also suggests that, even when the mechanical life limit of the HEPA train is reached, the degree of contamination could be reduced to such an extent that its means/classification of final disposal may be modified to further reduce cost. Pulsed jet filtration using metallic filter media is a practical and industrially proven means by which solids can be prevented from reaching the HEPA train and returned to the operator for disposal, whilst not interrupting the process flow through the system. Field experience and data to prove the contention is available. There are clearly benefits with regard to disposal in returning to the user the small quantities of dust that would otherwise lead to the contamination and blinding of the large volume of the filter train. A cost benefit analysis shows that this radical solution to HEPA cost amelioration can work. Presenting a review of the technology and its application to other areas illustrates that where gross dust removal or recovery is necessary, or where extreme conditions make traditional HEPA technologies impractical, metallic filtration systems can (and do) also offer economic and industrially real solutions.
Skip Nav Destination
The 11th International Conference on Environmental Remediation and Radioactive Waste Management
September 2–6, 2007
Bruges, Belgium
Conference Sponsors:
- Nuclear Division and Environmental Engineering Division
ISBN:
978-0-7918-4339-0
PROCEEDINGS PAPER
Cost and Waste Volume Reduction in HEPA Filter Trains by Effective Pre-Filtration
Chris Chadwick
Chris Chadwick
Microfiltrex, Fareham, Hampshire, England, UK
Search for other works by this author on:
Chris Chadwick
Microfiltrex, Fareham, Hampshire, England, UK
Paper No:
ICEM2007-7003, pp. 447-453; 7 pages
Published Online:
May 29, 2009
Citation
Chadwick, C. "Cost and Waste Volume Reduction in HEPA Filter Trains by Effective Pre-Filtration." Proceedings of the The 11th International Conference on Environmental Remediation and Radioactive Waste Management. 11th International Conference on Environmental Remediation and Radioactive Waste Management, Parts A and B. Bruges, Belgium. September 2–6, 2007. pp. 447-453. ASME. https://doi.org/10.1115/ICEM2007-7003
Download citation file:
11
Views
Related Proceedings Papers
Related Articles
Collection Efficiency and Pressure Drop of Needle Punched Filters
J. Eng. Ind (May,1976)
Numerical Prediction Method for Growth and Deformation of Filter Cakes
J. Fluids Eng (November,2006)
Characterization of the Degradation of HEPA Filters Protected by Different Spark Arrestors for Various Cutting Means and Cutting Conditions
ASME J of Nuclear Rad Sci (January,2023)
Related Chapters
Application Analysis and Experimental Study on Performance of Energy-Saving Electret Fiber
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)
Test Methods
Consensus on Operating Practices for the Sampling and Monitoring of Feedwater and Boiler Water Chemistry in Modern Industrial Boilers (CRTD-81)
The Parker Case and Institutional Confidence
A Centennial History of the American Society of Mechanical Engineers: 1880-1980