In the present study, a flow visualization and heat transfer investigation is carried out computationally on a flat plate with 10×1 array of impinging jets from a corrugated plate. This corrugated structure is an Anti-Cross Flow (ACF) technique which is proved to nullify the negative effects of cross-flow thus enhancing the overall cooling performance. Governing equations are solved using k-ω Shear Stress Transport (SST) turbulence model in commercial code FLUENT. The parameter variation considered for the present study are (i) three different heights of ACF corrugate (C/D = 1, 2 & 3) and (ii) two different jet-to-target plate spacing (H/D = 1 & 2). The dependence of ACF structure performance on the corrugate height (C/D) and the flow structure has been discussed in detail, therefore choosing an optimum corrugate height and visualizing the three-dimensional flow phenomena are the main objectives of the present study. The three-dimensional flow separation and heat transfer characteristics are explained with the help of skin friction lines, upwash fountains, wall eddies, counter-rotating vortex pair (CRVP), and plots of Nusselt number. It is found that the heat transfer performance is high at larger corrugate heights for both the jet-to-plate spacing. Moreover, the deterioration of the skin friction pattern corresponding to the far downstream impingement zones is greatly reduced with ACF structure, retaining more uniform heat transfer pattern even at low H/D values where the crossflow effects are more dominant in case of the conventional cooling structure. In comparison of the overall heat transfer performance the difference between C/D = 3 & C/D = 2 for H/D = 2 is significantly less, thus making the later as the optimal configuration in terms of reduced channel height.
Skip Nav Destination
ASME 2017 Heat Transfer Summer Conference
July 9–12, 2017
Bellevue, Washington, USA
Conference Sponsors:
- Heat Transfer Division
ISBN:
978-0-7918-5788-5
PROCEEDINGS PAPER
Computational Study of Flow and Heat Transfer With Anti Cross-Flows (ACF) Jet Impingement Cooling for Different Heights of Corrugate
Radheesh Dhanasegaran,
Radheesh Dhanasegaran
Chalmers University of Technology, Gothenburg, Sweden
Search for other works by this author on:
Ssheshan Pugazhendhi
Ssheshan Pugazhendhi
Indian Institute of Technology Madras, Chennai, India
Search for other works by this author on:
Radheesh Dhanasegaran
Chalmers University of Technology, Gothenburg, Sweden
Ssheshan Pugazhendhi
Indian Institute of Technology Madras, Chennai, India
Paper No:
HT2017-4783, V001T06A002; 7 pages
Published Online:
October 18, 2017
Citation
Dhanasegaran, R, & Pugazhendhi, S. "Computational Study of Flow and Heat Transfer With Anti Cross-Flows (ACF) Jet Impingement Cooling for Different Heights of Corrugate." Proceedings of the ASME 2017 Heat Transfer Summer Conference. Volume 1: Aerospace Heat Transfer; Computational Heat Transfer; Education; Environmental Heat Transfer; Fire and Combustion Systems; Gas Turbine Heat Transfer; Heat Transfer in Electronic Equipment; Heat Transfer in Energy Systems. Bellevue, Washington, USA. July 9–12, 2017. V001T06A002. ASME. https://doi.org/10.1115/HT2017-4783
Download citation file:
29
Views
Related Proceedings Papers
Related Articles
Jet Impingement Cooling of Chips Equipped With Multiple Cylindrical Pedestal Fins
J. Electron. Packag (September,2007)
Flow Visualization of Axisymmetric Impinging Jet on a Concave Surface
J. Heat Transfer (August,2018)
Effects of Target Channel Shapes on Double Swirl Cooling Performance at Gas Turbine Blade Leading Edge
J. Eng. Gas Turbines Power (July,2019)
Related Chapters
Vortex-Induced Vibration
Flow Induced Vibration of Power and Process Plant Components: A Practical Workbook
Random Turbulence Excitation in Single-Phase Flow
Flow-Induced Vibration Handbook for Nuclear and Process Equipment
Cavitating Structures at Inception in Turbulent Shear Flow
Proceedings of the 10th International Symposium on Cavitation (CAV2018)