A Steam Injector (SI) is a simple, compact, passive pump which also functions as a high-performance direct-contact compact heater. We are developing this innovative concept by applying the SI system to core injection systems in Emergency Core Cooling Systems (ECCS) to further improve the safety of nuclear power plants. Passive ECCS in nuclear power plants would be inherently very safe and would prevent serious accidents by keeping the core covered with water (Severe Accident-Free Concept). The Passive Core Coolant Injection System driven by a high-efficiency SI is one that, in an accident such as a loss of coolant accident (LOCA), attains a higher discharge pressure than the supply steam pressure used to inject water into the reactor by operating the SI using water stored in the pool as the water supply source and steam contained in the reactor as the source of pressurization energy. The passive SI equipment would replace large, rotating machines such as pumps and motors, so eliminating the possibility of such equipment failing. In this Si-driven Passive Core Coolant Injection System (SI-PCIS), redundancy will be provided to ensure that the water and steam supply valves to the SI open reliably, and when the valves open, the SI will automatically start to inject water into the core to keep the core covered with water. The SI used in SI-PCIS works for a range of steam pressure conditions, from atmosphere pressure through to high pressures, as confirmed by analytical simulations which were done based on comprehensive experimental data obtained using reduced scale SI. We did further simulations and evaluations of the core cooling and coolant injection performance of SI-PCIS in BWR using RETRAN-3D code, developed using EPRI and other utilities, for the case of small LOCA. Reactors equipped with passive safety systems — the gravity-driven core cooling/injection system (GDCS) and depressurization valves (DPV) — would inevitably end up having large LOCA, even if they are initially small LOCA, as depressurization valves are forcibly opened in order to inject coolant from the GDCS pool to the GDCS water head at up to ∼0.2MPa. On the other hand, our simulation demonstrated that SI-PCIS could prevent large LOCA occurring in reactors by having by coolant discharged into the core in the event of small LOCA or when DPV unexpectedly open.
Skip Nav Destination
ASME/JSME 2007 Thermal Engineering Heat Transfer Summer Conference collocated with the ASME 2007 InterPACK Conference
July 8–12, 2007
Vancouver, British Columbia, Canada
Conference Sponsors:
- Heat Transfer Division
ISBN:
0-7918-4275-4
PROCEEDINGS PAPER
Experiments and Analytical Simulation Work on an Innovative Steam-Injector-Driven Passive Core Injection Cooling System
Michitsugu Mori,
Michitsugu Mori
Tokyo Electric Power Company, Inc., Tokyo, Japan
Search for other works by this author on:
Tadashi Narabayashi,
Tadashi Narabayashi
Hokkaido University, Sapporo, Hokkaido, Japan
Search for other works by this author on:
Shuichi Ohmori,
Shuichi Ohmori
Tokyo Electric Power Company, Inc., Tokyo, Japan
Search for other works by this author on:
Fumitoshi Watanabe
Fumitoshi Watanabe
Tokyo Electric Power Company, Inc., Tokyo, Japan
Search for other works by this author on:
Michitsugu Mori
Tokyo Electric Power Company, Inc., Tokyo, Japan
Tadashi Narabayashi
Hokkaido University, Sapporo, Hokkaido, Japan
Shuichi Ohmori
Tokyo Electric Power Company, Inc., Tokyo, Japan
Fumitoshi Watanabe
Tokyo Electric Power Company, Inc., Tokyo, Japan
Paper No:
HT2007-32721, pp. 635-644; 10 pages
Published Online:
August 24, 2009
Citation
Mori, M, Narabayashi, T, Ohmori, S, & Watanabe, F. "Experiments and Analytical Simulation Work on an Innovative Steam-Injector-Driven Passive Core Injection Cooling System." Proceedings of the ASME/JSME 2007 Thermal Engineering Heat Transfer Summer Conference collocated with the ASME 2007 InterPACK Conference. ASME/JSME 2007 Thermal Engineering Heat Transfer Summer Conference, Volume 2. Vancouver, British Columbia, Canada. July 8–12, 2007. pp. 635-644. ASME. https://doi.org/10.1115/HT2007-32721
Download citation file:
11
Views
Related Proceedings Papers
Related Articles
Calculations of Combined Radiation and Convection Heat Transfer in Rod Bundles Under Emergency Cooling Conditions
J. Heat Transfer (August,1976)
The Plant Feature and Performance of Double MS (Modular Simplified and Medium Small Reactor)
J. Eng. Gas Turbines Power (January,2010)
Experimental Demonstration of Safety of AHWR during Stagnation Channel Break Condition in an Integral Test Loop
ASME J of Nuclear Rad Sci (April,2018)
Related Chapters
Insights and Results of the Shutdown PSA for a German SWR 69 Type Reactor (PSAM-0028)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
Comparison of the Availability of Trip Systems for Reactors with Exothermal Reactions (PSAM-0361)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
Development and Structure of the German Common Cause Failure Data Pool (PSAM-0020)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)