The present study was aimed to evaluate the performance of prototype microchannel evaporators for the residential air-conditioning application using R-22 refrigerant under wet condition. Eight prototype evaporators were manufactured and tested using psychrometric calorimeter test facilities. Each evaporator consisted of two or three parallel flow heat exchangers connected with return pipes. The parallel flow heat exchanger had 41 parallel microchannel tubes that brazed into the inlet and outlet headers. The tube had 8 rectangular ports with the hydraulic diameter of 1.3 mm. The louvered fin had louver angle of 27°, louver pitch of 1.4 mm and flow depth of 18.8 mm. It was found that the flow area ratio had a great effect on the cooling capacity of the microchannel evaporator from experimental results of prototypes 4, 5 and 6, and there was an appropriate range for cooling capacity. The flow distribution characteristics were slightly affected by the pressure drop resulting from the configuration of the refrigerant flow at the exit of the evaporator like merging manifold, which means that it could be possible to reduce the manufacturing cost of the microchannel evaporator. Both refrigerant and air-side pressure drops for the best prototype evaporator were 28.6 kPa and 2.53 mmAq, respectively, which could be affordable for the residential air-conditioning application.
Skip Nav Destination
ASME 2005 Summer Heat Transfer Conference collocated with the ASME 2005 Pacific Rim Technical Conference and Exhibition on Integration and Packaging of MEMS, NEMS, and Electronic Systems
July 17–22, 2005
San Francisco, California, USA
Conference Sponsors:
- Heat Transfer Division and Electronic and Photonic Packaging Division
ISBN:
0-7918-4734-9
PROCEEDINGS PAPER
Performance Evaluation of Prototype Microchannel Evaporators for the Residential Air-Conditioning Application Available to Purchase
Honggi Cho,
Honggi Cho
Sungkyunkwan University, Suwon, Korea
Search for other works by this author on:
Keumnam Cho
Keumnam Cho
Sungkyunkwan University, Suwon, Korea
Search for other works by this author on:
Honggi Cho
Sungkyunkwan University, Suwon, Korea
Keumnam Cho
Sungkyunkwan University, Suwon, Korea
Paper No:
HT2005-72475, pp. 413-418; 6 pages
Published Online:
March 9, 2009
Citation
Cho, H, & Cho, K. "Performance Evaluation of Prototype Microchannel Evaporators for the Residential Air-Conditioning Application." Proceedings of the ASME 2005 Summer Heat Transfer Conference collocated with the ASME 2005 Pacific Rim Technical Conference and Exhibition on Integration and Packaging of MEMS, NEMS, and Electronic Systems. Heat Transfer: Volume 4. San Francisco, California, USA. July 17–22, 2005. pp. 413-418. ASME. https://doi.org/10.1115/HT2005-72475
Download citation file:
13
Views
Related Proceedings Papers
Related Articles
Experimental Investigation of the Hydraulic and Thermal Performance of a Phase Change Material Slurry in the Heat Exchangers
J. Thermal Sci. Eng. Appl (March,2011)
Performance Evaluation of a Window Room Air Conditioner With
Microchannel Condensers
J. Energy Resour. Technol (March,2002)
Capacity Control for Refrigeration and Air-Conditioning Systems: A Comparative Study
J. Energy Resour. Technol (March,2001)
Related Chapters
Characteristics, Components, and Performance of A/C System Exchangers
Heat Exchanger Engineering Techniques
Adding Surface While Minimizing Downtime
Heat Exchanger Engineering Techniques
Performance Testing of Combined Cycle Power Plant
Handbook for Cogeneration and Combined Cycle Power Plants, Second Edition