Development of an upper layer in enclosure fires has a significant effect on the characteristics of the ceiling jet and a direct influence on the placement and performance of fire detection/suppression devices. Detailed transient measurement of ceiling jet velocity and temperature profiles within an upper layer for small-scale fires (2.0 kW and ceiling height of 1 m) are used to analyze the predictions produced by the LAVENT computer fire model. While the model predictions have been compared with large-scale experimental results with fires as large as 33 MW and ceiling height of up to 22m, the large-scale measurements do not have high special resolution and the present work offers a more thorough analysis of the model prediction. Various radiative losses (10–25%) were used to produce predictions that matched the experimental data. Comparison of the small-scale experimental data with the predictions from LAVENT shows that the model, which uses unconfined ceiling jet correlations, does not capture the ceiling jet profile well and over predicts the upper layer temperature during the development of the layer. The peak temperature prediction requires a different radiative loss factor than that which matches the upper layer temperature. In general, the peak temperature measurements are within 10% of the measured value. The velocity is generally over predicted since the retardation of the jet momentum by the upper layer does not seem to be modeled accurately.
Skip Nav Destination
ASME 2003 Heat Transfer Summer Conference
July 21–23, 2003
Las Vegas, Nevada, USA
Conference Sponsors:
- Heat Transfer Division
ISBN:
0-7918-3694-0
PROCEEDINGS PAPER
Comparison of Measured Transient Ceiling Jet Temperature and Velocity Profiles in the Presence of an Upper Layer With Predictions by LAVENT Computer Fire Model
Vahid Motevalli,
Vahid Motevalli
George Washington University, Ashburn, VA
Search for other works by this author on:
Siamak Riahi
Siamak Riahi
George Washington University, Ashburn, VA
Search for other works by this author on:
Vahid Motevalli
George Washington University, Ashburn, VA
Siamak Riahi
George Washington University, Ashburn, VA
Paper No:
HT2003-47111, pp. 49-56; 8 pages
Published Online:
December 17, 2008
Citation
Motevalli, V, & Riahi, S. "Comparison of Measured Transient Ceiling Jet Temperature and Velocity Profiles in the Presence of an Upper Layer With Predictions by LAVENT Computer Fire Model." Proceedings of the ASME 2003 Heat Transfer Summer Conference. Heat Transfer: Volume 2. Las Vegas, Nevada, USA. July 21–23, 2003. pp. 49-56. ASME. https://doi.org/10.1115/HT2003-47111
Download citation file:
6
Views
Related Proceedings Papers
Related Articles
Flow and Heat Transfer Due to a Buoyant Ceiling Jet Turning Downward at a Corner
J. Heat Transfer (February,1996)
The Buoyant Plume-Driven Adiabatic Ceiling Temperature Revisited
J. Heat Transfer (November,1986)
Heat Transfer From a Buoyant Plume to an Unconfined Ceiling
J. Heat Transfer (August,1982)
Related Chapters
Applications for Operation
Pipeline System Automation and Control
Ant Colony and Degraded Ceiling for Redundancy Allocation (PSAM-0421)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
User-Interactive Futuristic Displays Based on PIC Microcontroller
International Conference on Computer and Computer Intelligence (ICCCI 2011)