The refrigeration Brayton cycle, which has been used extensively in various industries, has an excellent potential for use in automotive air conditioning applications. However, the air-cycle system has a couple of drawbacks including fog generation and low cycle efficiency. In this research project, an air-to-air heat exchanger called a ‘mixer’ is designed and used at the outlet of a refrigeration Brayton cycle. The primary function of the mixer is to remove moisture from the secondary warm airflow into the system. Successful moisture removal from the secondary airflow results in achieving the second function of fog dissipation from the primary cold airflow. In order for the system to perform appropriately, the moisture removal rate must be kept at the highest possible rate. The experimental results from this research project reveal that to enhance moisture removal rate, one may either increase the primary cold airflow rate, decrease the secondary warm airflow rate, or the combination of the above airflow adjustments. Furthermore, based on experimental results, one may speculate that there is an optimum point in decreasing the secondary airflow rate. However, in increasing the primary airflow rate, one must be aware of the pressure drop through the cold side of the mixer as the higher pressure drop results in higher power consumption for the Brayton cycle. It is important to point out that appropriate levels of the primary and secondary airflows impacts the mixer effectiveness, and that for a constant cold airflow rate, decreasing the warm airflow rate below the cold airflow rate results in higher effectiveness.
Skip Nav Destination
ASME 2004 Heat Transfer/Fluids Engineering Summer Conference
July 11–15, 2004
Charlotte, North Carolina, USA
Conference Sponsors:
- Heat Transfer Division and Fluids Engineering Division
ISBN:
0-7918-4692-X
PROCEEDINGS PAPER
Experimental Analysis of an Air-to-Air Heat Exchanger for Use in a Refrigeration Brayton Cycle
Alireza Kargar,
Alireza Kargar
Kansas State University, Manhattan, KS
Search for other works by this author on:
Mohammad H. Hosni,
Mohammad H. Hosni
Kansas State University, Manhattan, KS
Search for other works by this author on:
Steve Eckels,
Steve Eckels
Kansas State University, Manhattan, KS
Search for other works by this author on:
Tomas Gielda
Tomas Gielda
Visteon Company
Search for other works by this author on:
Alireza Kargar
Kansas State University, Manhattan, KS
Mohammad H. Hosni
Kansas State University, Manhattan, KS
Steve Eckels
Kansas State University, Manhattan, KS
Tomas Gielda
Visteon Company
Paper No:
HT-FED2004-56544, pp. 195-202; 8 pages
Published Online:
February 24, 2009
Citation
Kargar, A, Hosni, MH, Eckels, S, & Gielda, T. "Experimental Analysis of an Air-to-Air Heat Exchanger for Use in a Refrigeration Brayton Cycle." Proceedings of the ASME 2004 Heat Transfer/Fluids Engineering Summer Conference. Volume 3. Charlotte, North Carolina, USA. July 11–15, 2004. pp. 195-202. ASME. https://doi.org/10.1115/HT-FED2004-56544
Download citation file:
5
Views
Related Proceedings Papers
Related Articles
Experimental Investigation of the Hydraulic and Thermal Performance of a Phase Change Material Slurry in the Heat Exchangers
J. Thermal Sci. Eng. Appl (March,2011)
Mechanical Expansion of Thick-Walled Microgroove Tube for High Pressure ACR System
J. Pressure Vessel Technol (April,2011)
The Development of
Performance Prediction Methods for an Automotive CO 2 A/C
Cycle
J. Thermal Sci. Eng. Appl (June,2011)
Related Chapters
An Analysis of the Feasibility of Photoelectric Technique Applied in Defrost-Control
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)
Modeling Building Air Conditioning Energy Consumption in Dense Urban Environments
Handbook of Integrated and Sustainable Buildings Equipment and Systems, Volume I: Energy Systems
Characteristics, Components, and Performance of A/C System Exchangers
Heat Exchanger Engineering Techniques