Various rib turbulator geometries have been used earlier to investigate the heat transfer and fluid flow characteristics owing to its vast industrial applications. Permeable ribs are reported to provide better performance in terms of heat transfer enhancement and pressure penalty. The trapezoidal rib with variable downstream chamfering and a centrally placed longitudinal slit has been used for the detailed flow field and heat transfer investigations using particle image velocimetry and liquid crystal thermography. Objective of the present work is to study the combined effect of rib chamfering along with a continuous slit and establish an understanding of the underlying flow mechanism and the corresponding heat transfer distribution. Experiments were carried out for hydraulic diameter based Reynolds numbers of 61480 in a rectangular duct for flow over rib with 12.5% blockage ratio and 25% open area ratio. The chamfer angles were varied from 0 to 20 degree. It has been observed that the slitted rib cause shorter reattachment length and reduced pressure penalty as compared to its solid counterpart.
Skip Nav Destination
ASME 2012 Gas Turbine India Conference
December 1, 2012
Mumbai, Maharashtra, India
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
978-0-7918-4516-5
PROCEEDINGS PAPER
LCT and PIV Investigations Behind Trapezoidal-Rib With a Slit Mounted on Bottom Wall of a Rectangular Duct
Md. Shaukat Ali,
Md. Shaukat Ali
Indian Institute of Technology Roorkee, Roorkee, India
Search for other works by this author on:
Andallib Tariq,
Andallib Tariq
Indian Institute of Technology Roorkee, Roorkee, India
Search for other works by this author on:
B. K. Gandhi
B. K. Gandhi
Indian Institute of Technology Roorkee, Roorkee, India
Search for other works by this author on:
Md. Shaukat Ali
Indian Institute of Technology Roorkee, Roorkee, India
Andallib Tariq
Indian Institute of Technology Roorkee, Roorkee, India
B. K. Gandhi
Indian Institute of Technology Roorkee, Roorkee, India
Paper No:
GTINDIA2012-9689, pp. 313-325; 13 pages
Published Online:
July 25, 2013
Citation
Ali, MS, Tariq, A, & Gandhi, BK. "LCT and PIV Investigations Behind Trapezoidal-Rib With a Slit Mounted on Bottom Wall of a Rectangular Duct." Proceedings of the ASME 2012 Gas Turbine India Conference. ASME 2012 Gas Turbine India Conference. Mumbai, Maharashtra, India. December 1, 2012. pp. 313-325. ASME. https://doi.org/10.1115/GTINDIA2012-9689
Download citation file:
31
Views
Related Proceedings Papers
Related Articles
Experimental Investigation of Local Heat Transfer Measurement Having Inclined Discrete Ribs of Solar Air Heater Duct Using LCT Technique
J. Thermal Sci. Eng. Appl (February,2022)
Experimental Investigation on Heat Transfer and Friction Factor in Open Matrix Subchannels
J. Heat Transfer (May,2021)
Related Chapters
Compressive Deformation of Hot-Applied Rubberized Asphalt Waterproofing
Roofing Research and Standards Development: 10th Volume
Laminar Fluid Flow and Heat Transfer
Applications of Mathematical Heat Transfer and Fluid Flow Models in Engineering and Medicine
Hydrodynamic Mass, Natural Frequencies and Mode Shapes
Flow-Induced Vibration Handbook for Nuclear and Process Equipment