High vibration problems resulting in damage to supports, instrument stubs etc. have been experienced in many compressor piping systems installed at different fertilizer plants. Investigations aimed at a solution to the problem included vibration measurements on the suction and discharge piping, and mathematical modeling of the piping. The measurements indicated presence of an excitation frequency in the range of 30–35% of the compressor running speed. Dynamic analysis of the piping system showed the presence of natural frequencies coinciding with or very near to the excitation frequencies. This has been further confirmed by impact tests. Analytical mode shapes clearly show that the antinodes match with high vibration zones observed at the site. The mathematical models were used to determine optimum configurations which would separate mechanical responses from excitation frequencies. These modifications have been implemented at site and the piping vibrations are within normal limits.