The changes in stiffness properties for a CAS matrix-Nicalon fiber unidirectional composite resulting from cyclic heating and cooling are presented. The measurements are made using an ultrasonic pulse-echo technique. It is shown that a significant decrease in stiffness is observed after 30 cycles.

This content is only available via PDF.