The MF-61 is a 6MW-class heavy duty gas turbine which was developed for cogeneration application. A single can type combustor with wide fuel flexibility and advanced high efficiency compressor has been adopted for this engine. The combustor outlet temperature is designed at 1150°C. This paper describes the design concepts of the machine, the design features, and the verification programs carried out in Takasago, Japan. The results of the full load shop test verified that the performance, the mechanical characteristic and the emission well satisfied the initial design goals.