In the present study a stationary open cycle gas turbine plant, including a thermal regenerator has been theoretically analyzed to assess the impact of steam addition in combustion air, on its performance. the effect of varying steam upto 15% air at different pressure ratios and turbine inlet temperatures have been reported. Mixing of steam in air results in higher values of cycle efficiency and increased specific work output, feasibility to generate steam needed for the purpose in a waste heat boiler have also been studied.