This paper describes the mechanical design features on TF-10 gas turbine. The TF-10 gas turbine features an intercooled centrifugal compressor and an annular combustor. A regenerator is added as a standard item. The ISO rating is 7.5 MW (10,000 hp) with a rotor inlet temperature (RIT) of 1116 C (2042 F) and a thermal efficiency of approximately 44 percent. Description of the combustion, rotors, stators, bearings and shafting is presented.