In this study, the unsteady behavior of a diffuser rotating stall in a centrifugal compressor with a vaned diffuser was investigated through experiments and numerical analyses. From the casing static pressure measurements, it was determined that the diffuser stall propagated at 25% of impeller rotational speed in the vaneless space. The numerical results revealed the presence of a typical vortical structure on the diffuser’s leading edge. Under partial flow condition, a tornado-type vortex was generated on the diffuser’s leading edge. Furthermore, a longitudinal vortex at the shroud/suction surface corner (i.e., leading edge vortex (LEV)) was induced by the rolling-up flow on the diffuser suction surface. As the velocity was decreased, the development of the tornado-type vortex and LEV forms a substantial flow blockage within the diffuser passages. Furthermore, the diffuser stall cell was caused by the systematic vortical structure which consisted of the tornado-type vortex, LEV, and vortex in the throat area of diffuser passages. In addition to this, the developed LEV interacted with the next diffuser leading edge and formed the throat area blockage with the passage of time. Then, the tornado-type vortex and LEV developed by the throat area blockage and diffuser stall cell, which was caused by the systematic vortical structure, propagated to the succeeding diffuser vane. Therefore, the diffuser stall in the centrifugal compressor was caused by the evolution of the tornado-type vortex and LEV.
Skip Nav Destination
ASME Turbo Expo 2017: Turbomachinery Technical Conference and Exposition
June 26–30, 2017
Charlotte, North Carolina, USA
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
978-0-7918-5081-7
PROCEEDINGS PAPER
Unsteady Behavior of Diffuser Stall in a Centrifugal Compressor With Vaned Diffuser
Nobumichi Fujisawa,
Nobumichi Fujisawa
Waseda University, Tokyo, Japan
Search for other works by this author on:
Yutaka Ohta
Yutaka Ohta
Waseda University, Tokyo, Japan
Search for other works by this author on:
Nobumichi Fujisawa
Waseda University, Tokyo, Japan
Daiki Ema
Waseda University, Tokyo, Japan
Yutaka Ohta
Waseda University, Tokyo, Japan
Paper No:
GT2017-63400, V02DT46A005; 11 pages
Published Online:
August 17, 2017
Citation
Fujisawa, N, Ema, D, & Ohta, Y. "Unsteady Behavior of Diffuser Stall in a Centrifugal Compressor With Vaned Diffuser." Proceedings of the ASME Turbo Expo 2017: Turbomachinery Technical Conference and Exposition. Volume 2D: Turbomachinery. Charlotte, North Carolina, USA. June 26–30, 2017. V02DT46A005. ASME. https://doi.org/10.1115/GT2017-63400
Download citation file:
118
Views
Related Proceedings Papers
Related Articles
Numerical Analysis of the Vaned Diffuser of a Transonic Centrifugal Compressor
J. Turbomach (October,2010)
A Numerical Investigation on the Volute/Diffuser Interaction Due to the Axial Distortion at the Impeller Exit
J. Fluids Eng (September,2001)
Related Chapters
Introduction
Design and Analysis of Centrifugal Compressors
Introduction
Mixed-flow Pumps: Modeling, Simulation, and Measurements
Other Components and Variations
Axial-Flow Compressors