Film cooling designs are often evaluated experimentally and characterized in terms of their spatial distributions of adiabatic effectiveness, η, which is the nondimensionalized form of the adiabatic wall temperature, Taw. Additionally, film cooling may alter the convective heat transfer coefficient with the possibility of an increase in h that offsets the benefits of reduced Taw. It is therefore necessary to combine these two effects to give some measure of the benefit of film cooling. The most frequently used method is the net heat flux reduction, which gives the fractional reduction in heat flux that accompanies film cooling for the hypothetical case of constant wall temperature. NHFR is imperfect in part due to the fact that this assumption does not account for the primary purpose of film cooling — to reduce the metal temperature to an acceptable level. In the present work we present an alternative method of evaluating film cooling performance that yields the reduction in metal temperature, or in the nondimensional sense, an increase in ϕ that would be predicted with film cooling. This Δϕ approach is then applied using experimentally obtained η and h/h0 values on a simulated turbine blade leading edge region. The delta-phi approach agrees well with the legacy NHFR technique in terms of the binary question of whether the film cooling is beneficial or detrimental, but provides greater insight into the temperature reduction that a film cooling design would provide an actual turbine component. For example, instead of giving an area-averaged NHFR = 0.67 (indicating a 67% reduction in heat flux through film cooling) on the leading edge region with M = 0.5, the Δϕ approach indicates an increase in ϕ of 0.061 (or a 61 K surface temperature decrease with a notional value of T∞ - Tc = 1000 K). Alternatively, the technique may be applied to predict the maximum allowable increase in T∞ against which a film cooling scheme could protect.
Skip Nav Destination
ASME Turbo Expo 2015: Turbine Technical Conference and Exposition
June 15–19, 2015
Montreal, Quebec, Canada
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
978-0-7918-5672-7
PROCEEDINGS PAPER
The Delta Phi Method of Evaluating Overall Film Cooling Performance
James L. Rutledge,
James L. Rutledge
Air Force Institute of Technology, Wright Patterson AFB, OH
Search for other works by this author on:
Marc D. Polanka,
Marc D. Polanka
Air Force Institute of Technology, Wright Patterson AFB, OH
Search for other works by this author on:
David G. Bogard
David G. Bogard
University of Texas at Austin, Austin, TX
Search for other works by this author on:
James L. Rutledge
Air Force Institute of Technology, Wright Patterson AFB, OH
Marc D. Polanka
Air Force Institute of Technology, Wright Patterson AFB, OH
David G. Bogard
University of Texas at Austin, Austin, TX
Paper No:
GT2015-43288, V05BT13A018; 9 pages
Published Online:
August 12, 2015
Citation
Rutledge, JL, Polanka, MD, & Bogard, DG. "The Delta Phi Method of Evaluating Overall Film Cooling Performance." Proceedings of the ASME Turbo Expo 2015: Turbine Technical Conference and Exposition. Volume 5B: Heat Transfer. Montreal, Quebec, Canada. June 15–19, 2015. V05BT13A018. ASME. https://doi.org/10.1115/GT2015-43288
Download citation file:
34
Views
Related Proceedings Papers
Related Articles
A REVIEW OF SECONDARY COMBUSTION ON TURBINE BLADE COOLING
J. Turbomach (January,0001)
An Experimental and Numerical Investigation of Near Cooling Hole Heat Fluxes on a Film-Cooled Turbine Blade
J. Turbomach (January,1989)
Clocking Effects of Inlet Nonuniformities in a Fully Cooled High-Pressure Vane: A Conjugate Heat Transfer Analysis
J. Turbomach (February,2016)
Related Chapters
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Basic Concepts
Design & Analysis of ASME Boiler and Pressure Vessel Components in the Creep Range
Detailed Aerodynamic Design of Radial-Inflow Turbine Components
Turbine Aerodynamics: Axial-Flow and Radial-Flow Turbine Design and Analysis