This study deals with the studies of the effect of flow control double devices (DFCDs) on turbine vane film cooling. Aiming for improving film effectiveness, two semi-spheroid DFCDs per pitch were attached to the vane surface upstream of the cooling hole. Although the DFCDs were successfully applied to the flat plate film cooling in the previous study, the applicability to the turbine vane was to be investigated. In order to observe the flow field in detail, RANS simulation was conducted first. The DFCDs were installed upstream of each cooling hole of the pressure and suction sides of the vane to investigate the effect of the device position. In this paper, the effects of blowing ratio and cooling hole pitch were also investigated. The results obtained by CFD showed that the vortex generated from DFCD suppressed lift off of the secondary air. As a result, the film effectiveness became significantly higher than that without DFCD condition. Moreover, the improvement in the film effectiveness by DFCD was observed by both of the pressure and suction sides of the turbine vane. Based on the findings through RANS simulation, adiabatic effectiveness and total pressure loss coefficient measurement were performed in a linear cascade test facility. The experiment confirmed that the film effectiveness was improved when DFCDs existed.
Skip Nav Destination
ASME Turbo Expo 2015: Turbine Technical Conference and Exposition
June 15–19, 2015
Montreal, Quebec, Canada
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
978-0-7918-5672-7
PROCEEDINGS PAPER
Improvement of Turbine Vane Film Cooling Performance by Double Flow Control Devices Available to Purchase
Hirokazu Kawabata,
Hirokazu Kawabata
Iwate University, Iwate, Japan
Search for other works by this author on:
Ken-ichi Funazaki,
Ken-ichi Funazaki
Iwate University, Iwate, Japan
Search for other works by this author on:
Hisato Tagawa,
Hisato Tagawa
Mitsubishi Hitachi Power Systems, Ltd, Ibaraki, Japan
Search for other works by this author on:
Yasuhiro Horiuchi
Yasuhiro Horiuchi
Mitsubishi Hitachi Power Systems, Ltd, Ibaraki, Japan
Search for other works by this author on:
Hirokazu Kawabata
Iwate University, Iwate, Japan
Ken-ichi Funazaki
Iwate University, Iwate, Japan
Yuya Suzuki
Iwate University, Iwate, Japan
Hisato Tagawa
Mitsubishi Hitachi Power Systems, Ltd, Ibaraki, Japan
Yasuhiro Horiuchi
Mitsubishi Hitachi Power Systems, Ltd, Ibaraki, Japan
Paper No:
GT2015-44026, V05BT12A052; 10 pages
Published Online:
August 12, 2015
Citation
Kawabata, H, Funazaki, K, Suzuki, Y, Tagawa, H, & Horiuchi, Y. "Improvement of Turbine Vane Film Cooling Performance by Double Flow Control Devices." Proceedings of the ASME Turbo Expo 2015: Turbine Technical Conference and Exposition. Volume 5B: Heat Transfer. Montreal, Quebec, Canada. June 15–19, 2015. V05BT12A052. ASME. https://doi.org/10.1115/GT2015-44026
Download citation file:
18
Views
Related Proceedings Papers
Related Articles
Comparison of RANS and Detached Eddy Simulation Modeling Against Measurements of Leading Edge Film Cooling on a First-Stage Vane
J. Turbomach (May,2017)
Improving Purge Air Cooling Effectiveness by Engineered End-Wall Surface Structures—Part II: Turbine Cascade
J. Turbomach (September,2018)
Separated Flow Transition on an LP Turbine Blade With Pulsed Flow Control
J. Turbomach (April,2008)
Related Chapters
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Thermodynamic Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Dynamic Behavior of Pumping Systems
Pipeline Pumping and Compression Systems: A Practical Approach