A highly loaded transonic fan with a splittered rotor and maximum pressure ratio of 2 has been tested at the Naval Post-graduate School. Temperatures on the casing outer wall have been measured using thermocouples in order to assess the heat transfer. An axisymmetric heat transfer analysis has shown that the heat transfer downstream of the rotor through the casing leads to an overstatement of the experimental efficiency by 0.36% and 0.29% for 100% and 90% speed respectively. Just above the rotor is an abradable material that can be considered adiabatic. Thus heat escapes only aft of the rotor and upstream of the total pressure and total temperature probes. For rotors without an adiabatic casing, the effect would be considerably higher. This has a large effect on the exit total temperature profiles which are often not matched well with CFD using an adiabatic boundary condition. In addition, heat transfer coefficients have been determined that can be used to assess other compressor applications.
Skip Nav Destination
ASME Turbo Expo 2015: Turbine Technical Conference and Exposition
June 15–19, 2015
Montreal, Quebec, Canada
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
978-0-7918-5663-5
PROCEEDINGS PAPER
Measured Heat Transfer in a Transonic Fan Rig at Casing With Implications on Performance
Mark G. Turner,
Mark G. Turner
University of Cincinnati, Cincinnati, OH
Search for other works by this author on:
Ahmed Nemnem,
Ahmed Nemnem
University of Cincinnati, Cincinnati, OH
Search for other works by this author on:
Anthony J. Gannon,
Anthony J. Gannon
Naval Postgraduate School, Monterey, CA
Search for other works by this author on:
Garth V. Hobson,
Garth V. Hobson
Naval Postgraduate School, Monterey, CA
Search for other works by this author on:
Wolfgang Sanz
Wolfgang Sanz
Graz University of Technology, Graz, Austria
Search for other works by this author on:
Mark G. Turner
University of Cincinnati, Cincinnati, OH
Ahmed Nemnem
University of Cincinnati, Cincinnati, OH
Anthony J. Gannon
Naval Postgraduate School, Monterey, CA
Garth V. Hobson
Naval Postgraduate School, Monterey, CA
Wolfgang Sanz
Graz University of Technology, Graz, Austria
Paper No:
GT2015-43482, V02AT37A039; 8 pages
Published Online:
August 12, 2015
Citation
Turner, MG, Nemnem, A, Gannon, AJ, Hobson, GV, & Sanz, W. "Measured Heat Transfer in a Transonic Fan Rig at Casing With Implications on Performance." Proceedings of the ASME Turbo Expo 2015: Turbine Technical Conference and Exposition. Volume 2A: Turbomachinery. Montreal, Quebec, Canada. June 15–19, 2015. V02AT37A039. ASME. https://doi.org/10.1115/GT2015-43482
Download citation file:
16
Views
0
Citations
Related Proceedings Papers
Related Articles
The Effect of Wall Thermal Boundary Condition on Natural Convective Shutdown Cooling in a Gas Turbine
J. Turbomach (November,2021)
Effect of Fouling on Temperature Measurement Error and a Solution
J. Heat Transfer (May,1998)
Thermal Modeling of an Intermediate Pressure Steam Turbine by Means of Conjugate Heat Transfer—Simulation and Validation
J. Eng. Gas Turbines Power (March,2017)
Related Chapters
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Natural Gas Transmission
Pipeline Design & Construction: A Practical Approach, Third Edition
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential