This paper presents a comparative analytical study of using water and R-134a as cooling medium in the condenser of a steam power plant (SPP). In this study, a shell-and-tube cross-flow heat exchanger has been considered. Because of its direct effect on cycle thermal efficiency, the condenser of the SPP has been continuously improved over the years. One of the ways of increasing the performance of a SPP is by reducing the condenser pressure and using low temperature cooling medium in the condenser. The lower the temperature of the cooling fluid circulating through the condenser tubes, the faster will be the steam condensation. This process increases the condensation rate as well as condenser heat transfer rate. Refrigerants have much lower temperatures and much higher heat transfer rates than water. In this comparative study of using R-134a or water as a cooling fluid in the condenser of a SPP, steam enters the shell side of a single-pass horizontal condenser and the condensate is collected at the bottom. Cooling fluid, “water or R-134a”, is fed into the tubes. The results of the analytical study indicated higher condensation rates and heat transfer for R-134a than water. Moreover, the exergetic and exergy efficiency analysis revealed that R-134a has higher values than water, which increase the power plant thermal efficiency and reduce the condenser size.
Skip Nav Destination
ASME Turbo Expo 2014: Turbine Technical Conference and Exposition
June 16–20, 2014
Düsseldorf, Germany
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
978-0-7918-4573-8
PROCEEDINGS PAPER
Comparative Study of Using Water and R-134a as Cooling Medium in the Condenser of a Steam Power Plant
Khaled Yousef,
Khaled Yousef
Menoufia University, Menoufia, Egypt
Search for other works by this author on:
Abebayehu Assefa,
Abebayehu Assefa
Addis Ababa University, Addis Ababa, Ethiopia
Search for other works by this author on:
Ahmed Hegazy,
Ahmed Hegazy
Menoufia University, Menoufia, Egypt
Search for other works by this author on:
Abraham Engeda
Abraham Engeda
Michigan State University, East Lansing, MI
Search for other works by this author on:
Khaled Yousef
Menoufia University, Menoufia, Egypt
Abebayehu Assefa
Addis Ababa University, Addis Ababa, Ethiopia
Ahmed Hegazy
Menoufia University, Menoufia, Egypt
Abraham Engeda
Michigan State University, East Lansing, MI
Paper No:
GT2014-25034, V05CT20A002; 9 pages
Published Online:
September 18, 2014
Citation
Yousef, K, Assefa, A, Hegazy, A, & Engeda, A. "Comparative Study of Using Water and R-134a as Cooling Medium in the Condenser of a Steam Power Plant." Proceedings of the ASME Turbo Expo 2014: Turbine Technical Conference and Exposition. Volume 5C: Heat Transfer. Düsseldorf, Germany. June 16–20, 2014. V05CT20A002. ASME. https://doi.org/10.1115/GT2014-25034
Download citation file:
20
Views
Related Proceedings Papers
Related Articles
Comparative Study of Using R-410A, R-407C, R-22, and R-134a as Cooling Medium in the Condenser of a Steam Power Plant
J. Eng. Gas Turbines Power (February,2015)
Exergy Analysis of Condensation of a Binary Mixture With One Noncondensable Component in a Shell and Tube Condenser
J. Heat Transfer (August,2008)
Simulation and Experimental Analysis of a Solar Driven Absorption Chiller With Partially Wetted Evaporator
J. Sol. Energy Eng (February,2010)
Related Chapters
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies
Engineering and Physical Modeling of Power Plant Cooling Systems
Thermal Power Plant Cooling: Context and Engineering
Threshold Functions
Closed-Cycle Gas Turbines: Operating Experience and Future Potential