Detailed numerical and experimental investigations of film cooling effectiveness were conducted on the blade tips of the first rotor row pertaining to a three-stage research turbine. Four different blade tip ejection configurations were utilized to determine the impact of the hole arrangements on the film cooling effectiveness. plane tip with tip hole cooling, squealer tip with tip hole cooling, plane tip with pressure-side-edge compound angle hole cooling and squealer tip with pressure-side-edge compound angle hole cooling. To avoid rotor imbalance, every pair is installed radially. Film cooling effectiveness measurements were performed for three blowing ratios (M) of 0.75, 1.25 and 1.75. Film cooling data was also obtained for three rotational speeds; 3000 rpm (reference condition), 2550 rpm and 2000 rpm. Film cooling measurements were performed using pressure sensitive paint (PSP) technique. In a parallel effort, extensive numerical investigations of the above configurations were performed to give a better view of flow behavior using a commercially available code. The experimental investigations were performed in the three-stage multi-purpose turbine research facility at the Turbomachinery Performance and Flow Research Laboratory (TPFL), Texas A&M University.
Skip Nav Destination
ASME Turbo Expo 2014: Turbine Technical Conference and Exposition
June 16–20, 2014
Düsseldorf, Germany
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
978-0-7918-4572-1
PROCEEDINGS PAPER
A Combined Experimental and Numerical Study of the Turbine Blade Tip Film Cooling Effectiveness Under Rotation Condition
M. Rezasoltani,
M. Rezasoltani
Texas A&M University, College Station, TX
Search for other works by this author on:
M. T. Schobeiri,
M. T. Schobeiri
Texas A&M University, College Station, TX
Search for other works by this author on:
J. C. Han
J. C. Han
Texas A&M University, College Station, TX
Search for other works by this author on:
M. Rezasoltani
Texas A&M University, College Station, TX
K. Lu
Texas A&M University, College Station, TX
M. T. Schobeiri
Texas A&M University, College Station, TX
J. C. Han
Texas A&M University, College Station, TX
Paper No:
GT2014-25625, V05BT13A019; 14 pages
Published Online:
September 18, 2014
Citation
Rezasoltani, M, Lu, K, Schobeiri, MT, & Han, JC. "A Combined Experimental and Numerical Study of the Turbine Blade Tip Film Cooling Effectiveness Under Rotation Condition." Proceedings of the ASME Turbo Expo 2014: Turbine Technical Conference and Exposition. Volume 5B: Heat Transfer. Düsseldorf, Germany. June 16–20, 2014. V05BT13A019. ASME. https://doi.org/10.1115/GT2014-25625
Download citation file:
48
Views
Related Proceedings Papers
Related Articles
Film-Cooling Effectiveness on a Rotating Turbine Platform Using Pressure Sensitive Paint Technique
J. Turbomach (October,2010)
Prediction of Film Cooling and Heat Transfer on a Rotating Blade Platform With Stator-Rotor Purge and Discrete Film-Hole Flows in a 1 - 1 2 Turbine Stage
J. Turbomach (October,2009)
Turbine Blade Platform Film Cooling With Typical Stator-Rotor Purge Flow and Discrete-Hole Film Cooling
J. Turbomach (October,2009)
Related Chapters
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Introduction
Turbine Aerodynamics: Axial-Flow and Radial-Flow Turbine Design and Analysis