Large axial flow fans are used in forced draft air cooled heat exchangers (ACHEs). Previous studies have shown that adverse operating conditions cause certain sectors of the fan, or the fan as a whole to operate at very low flow rates, thereby reducing the cooling effectiveness of the ACHE. The present study is directed towards the experimental and numerical analyses of the flow in the vicinity of an axial flow fan during low flow rates. This is done to obtain the global flow structure up and downstream of the fan. A near-free-vortex fan, designed for specific application in ACHEs, is used for the investigation. Experimental fan testing was conducted in a British Standard 848, type A fan test facility, to obtain the fan characteristic. Both steady-state and time-dependent numerical simulations were performed, depending on the operating condition of the fan, using the Realizable k-ε turbulence model. Good agreement is found between the numerically and experimentally obtained fan characteristic data. Using data from the numerical simulations, the time and circumferentially averaged flow field is presented. At the design flow rate the downstream fan jet mainly moves in the axial and tangential direction, as expected for a free-vortex design criteria, with a small amount of radial flow that can be observed. As the flow rate through the fan is decreased, it is evident that the down-stream fan jet gradually shifts more diagonally outwards, and the region where reverse flow occur between the fan jet and the fan rotational axis increases. At very low flow rates the flow close to the tip reverses through the fan, producing a small recirculation zone as well as swirl at certain locations upstream of the fan.
Skip Nav Destination
ASME Turbo Expo 2014: Turbine Technical Conference and Exposition
June 16–20, 2014
Düsseldorf, Germany
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
978-0-7918-4557-8
PROCEEDINGS PAPER
Investigation of the Flow Field in the Vicinity of an Axial Flow Fan During Low Flow Rates
Francois G. Louw,
Francois G. Louw
University of Stellenbosch, Stellenbosch, South Africa
Search for other works by this author on:
Theodor W. von Backström,
Theodor W. von Backström
University of Stellenbosch, Stellenbosch, South Africa
Search for other works by this author on:
Sybrand J. van der Spuy
Sybrand J. van der Spuy
University of Stellenbosch, Stellenbosch, South Africa
Search for other works by this author on:
Francois G. Louw
University of Stellenbosch, Stellenbosch, South Africa
Theodor W. von Backström
University of Stellenbosch, Stellenbosch, South Africa
Sybrand J. van der Spuy
University of Stellenbosch, Stellenbosch, South Africa
Paper No:
GT2014-25927, V01AT10A016; 14 pages
Published Online:
September 18, 2014
Citation
Louw, FG, von Backström, TW, & van der Spuy, SJ. "Investigation of the Flow Field in the Vicinity of an Axial Flow Fan During Low Flow Rates." Proceedings of the ASME Turbo Expo 2014: Turbine Technical Conference and Exposition. Volume 1A: Aircraft Engine; Fans and Blowers. Düsseldorf, Germany. June 16–20, 2014. V01AT10A016. ASME. https://doi.org/10.1115/GT2014-25927
Download citation file:
24
Views
0
Citations
Related Proceedings Papers
Related Articles
Vortex Shedding as a Mechanism for Free Emboli Formation in Mechanical Heart Valves
J Biomech Eng (April,2000)
Effect of Tip Vortex Reduction on Air-Cooled Condenser Axial Flow Fan Performance: An Experimental Investigation
J. Turbomach (March,2022)
Overheating and Frequent Thermal Cycling of Outdoor Electronic Cabinets in Cold Climates
J. Electron. Packag (March,1999)
Related Chapters
Random Turbulence Excitation in Single-Phase Flow
Flow-Induced Vibration Handbook for Nuclear and Process Equipment
Direct Air Cooling and Fans
Thermal Management of Microelectronic Equipment
Direct Air Cooling and Fans
Thermal Management of Microelectronic Equipment, Second Edition