An experimental analysis of a real engine cooling scheme was performed on a test article replicating a slot injection and an effusion array with a central large dilution hole. Test section consists of a rectangular cross-section duct with a flat plate comprised of 270 holes arranged in 29 staggered rows (D = 1.65mm, Sx/D = 7.6, Sy/D = 6, L/D = 5.5, α = 30deg) and a dilution hole (D = 18.75mm) located at the 14th row. Both effusion and dilution holes are fed by a channel replicating combustor annulus, that allows to control cold gas side cross-flow parameters, especially in terms of Reynolds number of both annulus and effusion holes. Upstream the first row, a 6mm high slot, ensure the protection of the very first region of the liner. Final aim was the measurement of both heat transfer coefficient and Net Heat Flux Reduction of the cooling scheme, by means of a steady-state Thermochromic Liquid Crystals (TLC) technique with a thin Inconel heating foil. A data reduction procedure based on a Finite Element approach has been developed to take into account the non uniform heat generation and conduction due to the large amount of holes. Experiments were carried out considering the combined effects of slot, effusion and dilution holes. Three different effusion blowing ratios (BR = 3–5–7) are investigated, keeping constant the slot flow parameters (BR = 1.3). Results highlight a large influence of effusion blowing ratio on heat transfer coefficient. A steep increase was found in the first rows, while the large dilution hole does not influences significantly the heat transfer behaviour in the downstream area.
Skip Nav Destination
ASME Turbo Expo 2010: Power for Land, Sea, and Air
June 14–18, 2010
Glasgow, UK
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
978-0-7918-4399-4
PROCEEDINGS PAPER
Combined Effect of Slot Injection, Effusion Array and Dilution Hole on the Heat Transfer Coefficient of a Real Combustor Liner: Part 1—Experimental Analysis
Bruno Facchini,
Bruno Facchini
University of Florence, Firenze, Italy
Search for other works by this author on:
Francesco Maiuolo,
Francesco Maiuolo
University of Florence, Firenze, Italy
Search for other works by this author on:
Lorenzo Tarchi,
Lorenzo Tarchi
University of Florence, Firenze, Italy
Search for other works by this author on:
Daniele Coutandin
Daniele Coutandin
Avio S.P.A., Rivalta di Torino, TO, Italy
Search for other works by this author on:
Bruno Facchini
University of Florence, Firenze, Italy
Francesco Maiuolo
University of Florence, Firenze, Italy
Lorenzo Tarchi
University of Florence, Firenze, Italy
Daniele Coutandin
Avio S.P.A., Rivalta di Torino, TO, Italy
Paper No:
GT2010-22936, pp. 753-762; 10 pages
Published Online:
December 22, 2010
Citation
Facchini, B, Maiuolo, F, Tarchi, L, & Coutandin, D. "Combined Effect of Slot Injection, Effusion Array and Dilution Hole on the Heat Transfer Coefficient of a Real Combustor Liner: Part 1—Experimental Analysis." Proceedings of the ASME Turbo Expo 2010: Power for Land, Sea, and Air. Volume 4: Heat Transfer, Parts A and B. Glasgow, UK. June 14–18, 2010. pp. 753-762. ASME. https://doi.org/10.1115/GT2010-22936
Download citation file:
40
Views
0
Citations
Related Proceedings Papers
Related Articles
Determination of Convective Heat Flux on Steady-State Heat Transfer Surfaces With Arbitrarily Specified Boundaries
J. Heat Transfer (November,1996)
Effects of a Reacting Cross-Stream on Turbine Film Cooling
J. Eng. Gas Turbines Power (May,2010)
Novel Jet Impingement Cooling Geometry for Combustor Liner Backside Cooling
J. Thermal Sci. Eng. Appl (June,2009)
Related Chapters
Conclusion
Introduction to Finite Element, Boundary Element, and Meshless Methods: With Applications to Heat Transfer and Fluid Flow
Thermal Interface Resistance
Thermal Management of Microelectronic Equipment
Thermal Interface Resistance
Thermal Management of Microelectronic Equipment, Second Edition