The independent influences of vane trailing edge and purge cooling are studied in detail for a one-and-one-half stage transonic high-pressure turbine operating at design corrected conditions. This paper builds on the conclusions of Part I, which investigated the combined influence of all cooling circuits. Heat-flux measurements for the airfoil, platform, tip, and root of the turbine blade as well as the shroud and the vane side of the purge cavity are used to track the influence of cooling flow. By independently varying the coolant flow rate through the vane trailing edge or purge circuit, the region of influence of each circuit can be isolated. Vane trailing edge cooling is found to create the largest reductions in blade heat transfer. However, much of the coolant accumulates on the blade suction surface and little influence is observed for the pressure surface. In contrast, the purge cooling is able to cause small reductions in heat transfer on both the suction and pressure surfaces of the airfoil. Its region of influence is limited to near the hub, but given that the purge coolant mass flow rate is 1/8th that of the vane trailing edge, it is impressive that any impact is observed at all. The cooling contributions of these two circuits account for nearly all of the cooling reductions observed for all three circuits in Part I, indicating that the vane inner cooling circuit that feeds most of the vane film-cooling holes has little impact on the downstream blade heat transfer. Time-accurate pressure measurements provide further insight into the complex interactions in the purge region that govern purge coolant injection. While the pressures supplying the purge coolant and the overall coolant flow rate remain fairly constant, the interactions of the vane pressure field and the rotor pressure field create moving regions of high pressure and low pressure at the exit of the cavity. This results in pulsing regions of injection and ingestion.
Skip Nav Destination
ASME Turbo Expo 2010: Power for Land, Sea, and Air
June 14–18, 2010
Glasgow, UK
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
978-0-7918-4399-4
PROCEEDINGS PAPER
Heat Transfer for the Blade of a Cooled Stage and One-Half High-Pressure Turbine: Part II—Independent Influences of Vane Trailing Edge and Purge Cooling
R. M. Mathison,
R. M. Mathison
The Ohio State University, Columbus, OH
Search for other works by this author on:
C. W. Haldeman,
C. W. Haldeman
The Ohio State University, Columbus, OH
Search for other works by this author on:
M. G. Dunn
M. G. Dunn
The Ohio State University, Columbus, OH
Search for other works by this author on:
R. M. Mathison
The Ohio State University, Columbus, OH
C. W. Haldeman
The Ohio State University, Columbus, OH
M. G. Dunn
The Ohio State University, Columbus, OH
Paper No:
GT2010-22715, pp. 285-298; 14 pages
Published Online:
December 22, 2010
Citation
Mathison, RM, Haldeman, CW, & Dunn, MG. "Heat Transfer for the Blade of a Cooled Stage and One-Half High-Pressure Turbine: Part II—Independent Influences of Vane Trailing Edge and Purge Cooling." Proceedings of the ASME Turbo Expo 2010: Power for Land, Sea, and Air. Volume 4: Heat Transfer, Parts A and B. Glasgow, UK. June 14–18, 2010. pp. 285-298. ASME. https://doi.org/10.1115/GT2010-22715
Download citation file:
16
Views
Related Proceedings Papers
Related Articles
Heat Transfer and Film Cooling of Blade Tips and Endwalls
J. Turbomach (July,2012)
Film-Cooling Effectiveness on a Rotating Turbine Platform Using Pressure Sensitive Paint Technique
J. Turbomach (October,2010)
Related Chapters
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Experimental Investigation of Ventilated Supercavitation Under Unsteady Conditions
Proceedings of the 10th International Symposium on Cavitation (CAV2018)
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential