The high-temperature gas-cooled reactor (HTGR) technology is the only nuclear technology capable of achieving coolant temperatures as high as 950 °C and at the same time ensuring safe and efficient production of electricity, process steam and hydrogen. HTGR can be combined with a gas turbine to be gas turbine cycle with HTGR. This cycle can make use of high temperature (750–950°C) gas heated by HTGR to generate electricity with high efficiency. Because it breaks through the temperature limit of steam cycle and incorporates the inter-cooling and recuperating, so the gas turbine cycle with HTGR is expected to be a competing candidate for future concepts of high efficiency power generation. The performance of direct gas turbine with HTGR coupled with recuperating, inter-cooling and pre-cooling process was investigated. Considering the selection of working fluid, the thermal efficiency of gas turbine with HTGR with helium, nitrogen, carbon dioxide and their mixtures as the working fluid was compared. Then, the influence of different parameters such as turbine inlet temperature, pressure loss coefficient and recuperation effectiveness on cycle efficiency was analyzed. Some useful conclusions were drawn on the system performance.
Skip Nav Destination
ASME Turbo Expo 2010: Power for Land, Sea, and Air
June 14–18, 2010
Glasgow, UK
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
978-0-7918-4398-7
PROCEEDINGS PAPER
The Parameter Analysis on the Gas Turbine Cycle in a High Temperature Gas-Cooled Reactor Available to Purchase
Huisheng Zhang,
Huisheng Zhang
Shanghai Jiao Tong University, Shanghai, China
Search for other works by this author on:
Jiancheng Zhang,
Jiancheng Zhang
Waigaoqiao Power Plant of Shanghai, Shanghai, China
Search for other works by this author on:
Ming Su,
Ming Su
Shanghai Jiao Tong University, Shanghai, China
Search for other works by this author on:
Shilie Weng
Shilie Weng
Shanghai Jiao Tong University, Shanghai, China
Search for other works by this author on:
Huisheng Zhang
Shanghai Jiao Tong University, Shanghai, China
Jiancheng Zhang
Waigaoqiao Power Plant of Shanghai, Shanghai, China
Ming Su
Shanghai Jiao Tong University, Shanghai, China
Shilie Weng
Shanghai Jiao Tong University, Shanghai, China
Paper No:
GT2010-23124, pp. 753-758; 6 pages
Published Online:
December 22, 2010
Citation
Zhang, H, Zhang, J, Su, M, & Weng, S. "The Parameter Analysis on the Gas Turbine Cycle in a High Temperature Gas-Cooled Reactor." Proceedings of the ASME Turbo Expo 2010: Power for Land, Sea, and Air. Volume 3: Controls, Diagnostics and Instrumentation; Cycle Innovations; Marine. Glasgow, UK. June 14–18, 2010. pp. 753-758. ASME. https://doi.org/10.1115/GT2010-23124
Download citation file:
15
Views
Related Proceedings Papers
Related Articles
Heat Exchanger Design Considerations for Gas Turbine HTGR Power Plant
J. Eng. Power (April,1977)
A Novel High-Temperature Ejector-Topping Power Cycle
J. Eng. Gas Turbines Power (January,1994)
Materials Development for HTGR Heat Exchangers
J. Eng. Power (October,1983)
Related Chapters
Studies Performed
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Thermodynamic Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies