Previous research has shown that vane clocking, the circumferential indexing of adjacent vane rows with similar vane counts, can be an effective means to increase stage performance, reduce discrete frequency noise, and/or reduce the unsteady blade forces that can lead to high cycle fatigue. The objective of this research was to experimentally investigate the effects of vane clocking in an embedded compressor stage, focusing on stage performance. Experiments were performed in the intermediate-speed Purdue 3-Stage Compressor, which consists of an IGV followed by three stages. The IGV, Stator 1, and Stator 2 vane rows have identical vane counts, and the effects of vane clocking were studied on Stage 2. Much effort went into refining performance measurements to enable the detection of small changes in stage efficiency associated with vane clocking. At design loading, the change in stage efficiency between the maximum and minimum efficiency clocking configurations was 0.27 points. The maximum efficiency clocking configuration positioned the Stator 1 wake at the Stator 2 leading edge. This condition produced a shallower and thinner Stator 2 wake compared to the clocking configuration that located the wake in the middle of the Stator 2 passage. At high loading, the change in Stage 2 efficiency associated with vane clocking effects increased to 1.07 points; however, the maximum efficiency clocking configuration was the case where the Stator 1 wake passed through the middle of the downstream vane passage. Thus, impingement of the upstream vane wake on the downstream vane leading edge resulted in the best performance at design point but provided the lowest efficiency at an off-design condition.
Skip Nav Destination
ASME Turbo Expo 2008: Power for Land, Sea, and Air
June 9–13, 2008
Berlin, Germany
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
978-0-7918-4316-1
PROCEEDINGS PAPER
An Experimental Study of Vane Clocking Effects on Embedded Compressor Stage Performance Available to Purchase
Nicole L. Key,
Nicole L. Key
Purdue University, West Lafayette, IN
Search for other works by this author on:
Patrick B. Lawless,
Patrick B. Lawless
Purdue University, West Lafayette, IN
Search for other works by this author on:
Sanford Fleeter
Sanford Fleeter
Purdue University, West Lafayette, IN
Search for other works by this author on:
Nicole L. Key
Purdue University, West Lafayette, IN
Patrick B. Lawless
Purdue University, West Lafayette, IN
Sanford Fleeter
Purdue University, West Lafayette, IN
Paper No:
GT2008-51087, pp. 1973-1984; 12 pages
Published Online:
August 3, 2009
Citation
Key, NL, Lawless, PB, & Fleeter, S. "An Experimental Study of Vane Clocking Effects on Embedded Compressor Stage Performance." Proceedings of the ASME Turbo Expo 2008: Power for Land, Sea, and Air. Volume 6: Turbomachinery, Parts A, B, and C. Berlin, Germany. June 9–13, 2008. pp. 1973-1984. ASME. https://doi.org/10.1115/GT2008-51087
Download citation file:
13
Views
Related Proceedings Papers
Related Articles
The Influence of Turbulence on Wake Dispersion and Blade Row Interaction in an Axial Compressor
J. Turbomach (January,2006)
Experimental Reduction of Transonic Fan Forced Response by Inlet Guide Vane Flow Control
J. Turbomach (April,2010)
Analysis of Rotor-Stator-Interaction and Blade-to-Blade Measurements in a Two Stage Axial Flow Compressor
J. Turbomach (January,2011)
Related Chapters
Other Components and Variations
Axial-Flow Compressors
Introduction
Design and Analysis of Centrifugal Compressors
Aerodynamic Performance Analysis
Axial-Flow Compressors