With the increase in usage of gas turbines for power generation and given that natural gas resources continue to be depleted, it has become increasingly important to search for alternate fuels. One source of alternate fuels is coal derived synthetic fuels. Coal derived fuels, however, contain traces of ash and other contaminants that can deposit on vane and turbine surfaces affecting their heat transfer through reduced film-cooling. The endwall of a first stage vane is one such region that can be susceptible to depositions from these contaminants. This study uses a large-scale turbine vane cascade in which the following effects on film-cooling adiabatic effectiveness were investigated in the endwall region: the effect of near-hole deposition, the effect of partial film-cooling hole blockage, and the effect of spallation of a thermal barrier coating. The results indicated that deposits near the hole exit can sometimes improve the cooling effectiveness at the leading edge, but with increased deposition heights the cooling deteriorates. Partial hole blockage studies revealed that the cooling effectiveness deteriorates with increases in the number of blocked holes. Spallation studies showed that for a spalled endwall surface downstream of the leading edge cooling row, cooling effectiveness worsened with an increase in blowing ratio.
Skip Nav Destination
ASME Turbo Expo 2006: Power for Land, Sea, and Air
May 8–11, 2006
Barcelona, Spain
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
0-7918-4238-X
PROCEEDINGS PAPER
Effects of Surface Deposition, Hole Blockage, and TBC Spallation on Vane Endwall Film-Cooling Available to Purchase
N. Sundaram,
N. Sundaram
Virginia Polytechnic Institute and State University, Blacksburg, VA
Search for other works by this author on:
K. A. Thole
K. A. Thole
Virginia Polytechnic Institute and State University, Blacksburg, VA
Search for other works by this author on:
N. Sundaram
Virginia Polytechnic Institute and State University, Blacksburg, VA
K. A. Thole
Virginia Polytechnic Institute and State University, Blacksburg, VA
Paper No:
GT2006-90379, pp. 407-418; 12 pages
Published Online:
September 19, 2008
Citation
Sundaram, N, & Thole, KA. "Effects of Surface Deposition, Hole Blockage, and TBC Spallation on Vane Endwall Film-Cooling." Proceedings of the ASME Turbo Expo 2006: Power for Land, Sea, and Air. Volume 3: Heat Transfer, Parts A and B. Barcelona, Spain. May 8–11, 2006. pp. 407-418. ASME. https://doi.org/10.1115/GT2006-90379
Download citation file:
68
Views
Related Proceedings Papers
Related Articles
High-Pressure Turbine Deposition in Land-Based Gas Turbines From Various Synfuels
J. Eng. Gas Turbines Power (January,2007)
Deposition Near Film Cooling Holes on a High Pressure Turbine Vane
J. Turbomach (July,2012)
Related Chapters
Introduction
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies
Literature Survey of the Properties of Synthetic Fuels Derived from Coal
Stationary Gas Turbine Alternative Fuels