The main contributor to the high-cycle fatigue of compressor blades is the response to aerodynamic forcing functions generated by an upstream row of stators or inlet guide vanes. Resonant response to engine order excitation at certain rotor speeds can be especially damaging. Studies have shown that flow control by trailing edge blowing (TEB) can reduce stator wake strength and the amplitude of the downstream rotor blade vibrations generated by the unsteady stator-rotor interaction. In the present study, the effectiveness of TEB to reduce forced fan blade vibrations was evaluated in a modern single-stage transonic fan rig. Data was collected for multiple uniform full-span TEB conditions over a range of rotor speed including multiple modal resonance crossings. Resonant response sensitivity was generally characterized by a robust region of strong attenuation. The baseline resonant amplitude of the first torsion mode, which exceeded the endurance limit on the critical blade, was reduced by more than 80% with TEB at 1.0% of the total rig flow. The technique was also found to be modally robust; similar reductions were achieved for all tested modal crossings, including more than 90% reduction of the second LE bending response using 0.7% of the rig flow.
Skip Nav Destination
ASME Turbo Expo 2004: Power for Land, Sea, and Air
June 14–17, 2004
Vienna, Austria
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
0-7918-4171-5
PROCEEDINGS PAPER
Experimental Reduction of Transonic Fan Forced Response by IGV Flow Control
S. Todd Bailie,
S. Todd Bailie
Virginia Polytechnic Institute and State University, Blacksburg, VA
Search for other works by this author on:
Wing F. Ng,
Wing F. Ng
Virginia Polytechnic Institute and State University, Blacksburg, VA
Search for other works by this author on:
William W. Copenhaver
William W. Copenhaver
U.S. Air Force Research Laboratory, Wright-Patterson AFB, OH
Search for other works by this author on:
S. Todd Bailie
Virginia Polytechnic Institute and State University, Blacksburg, VA
Wing F. Ng
Virginia Polytechnic Institute and State University, Blacksburg, VA
William W. Copenhaver
U.S. Air Force Research Laboratory, Wright-Patterson AFB, OH
Paper No:
GT2004-53975, pp. 527-537; 11 pages
Published Online:
November 24, 2008
Citation
Bailie, ST, Ng, WF, & Copenhaver, WW. "Experimental Reduction of Transonic Fan Forced Response by IGV Flow Control." Proceedings of the ASME Turbo Expo 2004: Power for Land, Sea, and Air. Volume 6: Turbo Expo 2004. Vienna, Austria. June 14–17, 2004. pp. 527-537. ASME. https://doi.org/10.1115/GT2004-53975
Download citation file:
18
Views
Related Proceedings Papers
Related Articles
Experimental Reduction of Transonic Fan Forced Response by Inlet Guide Vane Flow Control
J. Turbomach (April,2010)
The Influence of Turbulence on Wake Dispersion and Blade Row Interaction in an Axial Compressor
J. Turbomach (January,2006)
Unsteady Aerodynamics and Aeroacoustics of a High-Bypass Ratio Fan Stage
J. Turbomach (January,2005)
Related Chapters
Other Components and Variations
Axial-Flow Compressors
Fluidelastic Instability of Tube Bundles in Single-Phase Flow
Flow-Induced Vibration Handbook for Nuclear and Process Equipment
Introduction
Design and Analysis of Centrifugal Compressors