The main contributor to the high-cycle fatigue of compressor blades is the response to aerodynamic forcing functions generated by an upstream row of stators or inlet guide vanes. Resonant response to engine order excitation at certain rotor speeds is especially damaging. Studies have shown that flow control by trailing edge blowing (TEB) can reduce stator wake strength and the amplitude of the downstream rotor blade vibrations generated by the unsteady stator-rotor interaction. In the present study, the effectiveness of TEB to reduce forced blade vibrations was evaluated in a modern transonic compressor rig. A row of wake generator (WG) vanes with TEB capability was installed upstream of the rotor, which was instrumented with strain gages. Data was collected with and without TEB at various rotor speeds involving resonance crossings. Using 0.8% of the compressor core flow for TEB along the full WG-span, rotor blade strain was reduced by 66% at the first torsional resonance crossing. Substantial reductions were also achieved with only partial span TEB. The results demonstrate the effectiveness of the TEB technique for reducing rotor vibrations in the complex flow environment of a closely-spaced transonic stage row. Moderate increases in stage performance were also measured.
Skip Nav Destination
ASME Turbo Expo 2002: Power for Land, Sea, and Air
June 3–6, 2002
Amsterdam, The Netherlands
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
0-7918-3606-1
PROCEEDINGS PAPER
Effects of Flow Control on Forced Response and Performance of a Transonic Compressor
S. Todd Bailie,
S. Todd Bailie
Virginia Polytechnic Institute and State University, Blacksburg, VA
Search for other works by this author on:
Wing F. Ng,
Wing F. Ng
Virginia Polytechnic Institute and State University, Blacksburg, VA
Search for other works by this author on:
Alfred L. Wicks,
Alfred L. Wicks
Virginia Polytechnic Institute and State University, Blacksburg, VA
Search for other works by this author on:
William W. Copenhaver
William W. Copenhaver
U.S. Air Force Research Laboratory, Wright-Patterson AFB, OH
Search for other works by this author on:
S. Todd Bailie
Virginia Polytechnic Institute and State University, Blacksburg, VA
Wing F. Ng
Virginia Polytechnic Institute and State University, Blacksburg, VA
Alfred L. Wicks
Virginia Polytechnic Institute and State University, Blacksburg, VA
William W. Copenhaver
U.S. Air Force Research Laboratory, Wright-Patterson AFB, OH
Paper No:
GT2002-30008, pp. 67-74; 8 pages
Published Online:
February 4, 2009
Citation
Bailie, ST, Ng, WF, Wicks, AL, & Copenhaver, WW. "Effects of Flow Control on Forced Response and Performance of a Transonic Compressor." Proceedings of the ASME Turbo Expo 2002: Power for Land, Sea, and Air. Volume 1: Turbo Expo 2002. Amsterdam, The Netherlands. June 3–6, 2002. pp. 67-74. ASME. https://doi.org/10.1115/GT2002-30008
Download citation file:
18
Views
Related Proceedings Papers
Related Articles
Experimental Reduction of Transonic Fan Forced Response by Inlet Guide Vane Flow Control
J. Turbomach (April,2010)
The Influence of Turbulence on Wake Dispersion and Blade Row Interaction in an Axial Compressor
J. Turbomach (January,2006)
Unsteady Aerodynamics and Aeroacoustics of a High-Bypass Ratio Fan Stage
J. Turbomach (January,2005)
Related Chapters
Other Components and Variations
Axial-Flow Compressors
Fluidelastic Instability of Tube Bundles in Single-Phase Flow
Flow-Induced Vibration Handbook for Nuclear and Process Equipment
Analysis on Double Resonances of Generator Stator and Rotor Coupling Rigid Model
International Conference on Computer Technology and Development, 3rd (ICCTD 2011)