To reduce vibration and noise level, the impeller and diffuser blade numbers inside an industrial compressor are typically chosen without common divisors. The shapes of volutes or collectors in these compressors are also not axis-symmetric. When impeller blades pass these asymmetric structures, the flow field in the compressor is time-dependent and three-dimensional. To obtain a fundamental physical understanding of these three-dimensional unsteady flow fields and assess their impact on the compressor performance, the flow field inside the compressors needs to be studied as a whole to include asymmetric and unsteady interaction between the compressor components. In current study, a unified three-dimensional numerical model was built for a transonic centrifugal compressor including impeller, diffusers, and volute. HFC 134a was used as the working fluid. The thermodynamic and transport properties of the refrigerant gas were modeled by the Martin-Hou equation of state and power laws, respectively. The three-dimensional unsteady flow field was simulated with a Navier-Stokes solver using the k-ε turbulent model. The overall performance parameters are obtained by integrating the field quantities. Both unsteady flow field and overall performance are analyzed comparatively for each component. The compressor was tested in a water chiller system instrumented to obtain both overall performance data and local flow field quantities. The experimental and numerical results agree well. The correlation between the overall compressor performance and local flow field quantities is defined. The methodology developed and data obtained in these studies can be applied to centrifugal compressor design and optimization.
Skip Nav Destination
ASME Turbo Expo 2001: Power for Land, Sea, and Air
June 4–7, 2001
New Orleans, Louisiana, USA
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
978-0-7918-7850-7
PROCEEDINGS PAPER
Comparative Study of Unsteady Flows in a Transonic Centrifugal Compressor With Vaneless and Vaned Diffusers
Michael M. Cui
Michael M. Cui
The Trane Company, La Crosse, WI
Search for other works by this author on:
Michael M. Cui
The Trane Company, La Crosse, WI
Paper No:
2001-GT-0297, V001T03A002; 15 pages
Published Online:
July 30, 2014
Citation
Cui, MM. "Comparative Study of Unsteady Flows in a Transonic Centrifugal Compressor With Vaneless and Vaned Diffusers." Proceedings of the ASME Turbo Expo 2001: Power for Land, Sea, and Air. Volume 1: Aircraft Engine; Marine; Turbomachinery; Microturbines and Small Turbomachinery. New Orleans, Louisiana, USA. June 4–7, 2001. V001T03A002. ASME. https://doi.org/10.1115/2001-GT-0297
Download citation file:
14
Views
Related Proceedings Papers
Related Articles
Unsteady Flow in a Turbocharger Centrifugal Compressor: Three-Dimensional Computational Fluid Dynamics Simulation and Numerical and Experimental Analysis of Impeller Blade Vibration
J. Turbomach (July,2006)
Investigation of Unsteady Flow Field in a Vaned Diffuser of a Transonic Centrifugal Compressor
J. Turbomach (October,2007)
Related Chapters
Introduction
Design and Analysis of Centrifugal Compressors
Other Components and Variations
Axial-Flow Compressors
Antilock-Braking System Using Fuzzy Logic
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3